MAXIMUM AND DEFAULT AC INPUT AND DC (bulk stage) OUTPUT VALUES

FX2012(M)T

AC Max = 12 AAC (Default = 10 AAC)

DC Max = 100 ADC

 

 

 

 

FX2524(M)T

AC Max = 14 AAC (Default = 12 AAC)

DC Max = 55

ADC

FX2532(M)T

AC Max = 14 AAC (Default = 12 AAC)

DC Max = 40

ADC

 

 

 

 

FX3048T

AC Max = 14 AAC (Default = 12 AAC)

DC Max = 35

ADC

 

 

 

VFX2812(M)

AC Max = 16 AAC (Default = 14 AAC)

DC Max = 125 ADC

VFX3524(M)

AC Max = 20 AAC (Default = 18 AAC)

DC Max = 85

ADC

 

 

 

 

VFX3232(M)

AC Max = 20 AAC (Default = 18 AAC)

DC Max = 60

ADC

 

 

 

 

VFX3648

AC Max = 20 AAC (Default = 18 AAC)

DC Max = 45

ADC

 

 

 

 

AC INPUT FREQUENCY RANGE

Note: If the AC input source is out of the range noted below, the FX will not connect or stay connected.

All FX Models

56 - 64 Hz

MAXIMUM AC OUTPUT CURRENT

This is the amount of surge current that the FX will quickly supply for a split second. Depending on the size of the surge, the FX can be overloaded for a minimum time of 5 seconds to a maximum time of 30 minutes.

All 12 VDC FXs

56 AAC per FX for 1 millisecond

 

 

All Other FXs

70 AAC per FX for 1 millisecond

 

 

MAXIMUM CONTINUOUS OUTPUT POWER

An FX Series Inverter/Charger’s model number indicates its maximum continuous output power by changing the last two digits to zeros. For instance, an FX2012MT has a maximum continuous output

power of 2000VA (volt-amps).

FX2012(M)T

2000 VA (VA = volt-Amps)

FX2024(M)T

2000 VA

FX2532(M)T

2500 VA

FX2548T

2500 VA

VFX2812(M)

2800 VA

VFX3524(M)

3500 VA

VFX3232(M)

3200 VA

VFX3648

3600 VA

 

 