MAXIMUM AND DEFAULT AC INPUT AND DC (bulk stage) OUTPUT VALUES
FX2012(M)T | AC Max = 12 AAC (Default = 10 AAC) | DC Max = 100 ADC | |
|
|
|
|
FX2524(M)T | AC Max = 14 AAC (Default = 12 AAC) | DC Max = 55 | ADC |
FX2532(M)T | AC Max = 14 AAC (Default = 12 AAC) | DC Max = 40 | ADC |
|
|
|
|
FX3048T | AC Max = 14 AAC (Default = 12 AAC) | DC Max = 35 | ADC |
|
|
| |
VFX2812(M) | AC Max = 16 AAC (Default = 14 AAC) | DC Max = 125 ADC | |
VFX3524(M) | AC Max = 20 AAC (Default = 18 AAC) | DC Max = 85 | ADC |
|
|
|
|
VFX3232(M) | AC Max = 20 AAC (Default = 18 AAC) | DC Max = 60 | ADC |
|
|
|
|
VFX3648 | AC Max = 20 AAC (Default = 18 AAC) | DC Max = 45 | ADC |
|
|
|
|
AC INPUT FREQUENCY RANGE
Note: If the AC input source is out of the range noted below, the FX will not connect or stay connected.
All FX Models
56 - 64 Hz
MAXIMUM AC OUTPUT CURRENT
This is the amount of surge current that the FX will quickly supply for a split second. Depending on the size of the surge, the FX can be overloaded for a minimum time of 5 seconds to a maximum time of 30 minutes.
All 12 VDC FXs | 56 AAC per FX for 1 millisecond |
|
|
All Other FXs | 70 AAC per FX for 1 millisecond |
|
|
MAXIMUM CONTINUOUS OUTPUT POWER
An FX Series Inverter/Charger’s model number indicates its maximum continuous output power by changing the last two digits to zeros. For instance, an FX2012MT has a maximum continuous output
power of 2000VA (volt-amps).
FX2012(M)T | 2000 VA (VA = |
FX2024(M)T | 2000 VA |
FX2532(M)T | 2500 VA |
FX2548T | 2500 VA |
VFX2812(M) | 2800 VA |
VFX3524(M) | 3500 VA |
VFX3232(M) | 3200 VA |
VFX3648 | 3600 VA |
|
|
31