Wayne-Dalton 5140, 5120 installation instructions idrive Installation

Models: 5120 5140

1 38
Download 38 pages 8.68 Kb
Page 20
Image 20
idrive® Installation

17

idrive® Installation

 

 

 

 

 

Tools Needed:

NOTE: See idrive® main installation and

 

 

 

owners manual for idrive® parts.

 

 

None

IMPORTANT: Right and left hand

 

 

 

 

 

 

is always determined from inside

Left Hand Side

 

 

the garage looking out.

TorqueMaster® Spring Tube

 

 

 

and Bearing profiles aligned

Motor

 

Lay the TorqueMaster® spring tube on

 

 

 

 

 

the floor (inside garage) in front of the

 

 

 

door with the labeled end to the left.

 

 

 

Look into the opener’s left side to

Right Hand End

 

 

ensure the left hand bearing and the

 

 

internal (black) sleeve are aligned with

of TorqueMaster®

 

 

Spring Tube

 

 

the TorqueMaster® spring tube profile.

 

 

 

 

 

IMPORTANT: Hold Opener by the

 

 

 

main body. Do NOT hold by the

 

 

 

Motor.

 

 

 

NOTE: Opener will not slide over the

 

 

 

TorqueMaster® spring tube label.

 

 

 

Attempting to slide opener over the left

 

 

 

end of the TorqueMaster® spring tube

 

 

 

can damage the internal electronics.

 

Right Hand Side

 

 

 

 

Once aligned, slide the opener onto the

 

TorqueMaster®

 

 

Spring Tube and

 

right hand end of the TorqueMaster®

 

 

 

Bearing profiles

 

spring tube. As the right end of the

 

aligned

 

TorqueMaster® spring tube enters the

 

 

 

internal (black) sleeve, rotate the

 

 

 

opener back and forth slightly to help

 

 

 

aid alignment.

 

 

 

Continue sliding the opener onto the

 

 

 

TorqueMaster® spring tube. Align the

 

 

 

right hand bearing with the

 

 

 

TorqueMaster® spring tube and slide

 

 

 

the opener completely onto the

 

 

 

TorqueMaster® spring tube until the

 

 

 

TorqueMaster® spring tube exits the

 

 

 

opener right hand bearing.

 

 

 

NOTE: Do not force the opener onto the

 

 

 

TorqueMaster® spring tube if

 

 

 

misalignment occurs.

 

 

 

Continue sliding the opener to the

 

 

 

center of the TorqueMaster® spring

 

 

 

tube.

 

Plug-in Motor

 

 

 

Power Cord

 

Plug the motor power cord into the

 

 

 

opener.

 

 

20

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer.

To find your Wayne-Dalton dealer; refer to your local yellow pages / business listings or go to Find a dealer area online at www.wayne-dalton.com

Page 20
Image 20
Wayne-Dalton 5140, 5120 installation instructions idrive Installation