Attaching Disconnect Cables

 

 

24

Attaching Disconnect Cables

Tools Needed:

NOTE: See idrive® main installation and

Pliers

owners manual for idrive® parts.

 

 

Attach the loose disconnect cable

 

(located in opener hardware bag) to the

 

opener with the “S” hook. Close both

 

ends of the “S” hook (with pliers) to lock

 

assembly together.

 

Thread the disconnect cable (behind the

 

counterbalance cable) through the hole

 

in the right hand end bracket; remove

 

all slack between opener and right end

 

bracket.

S-Hook

Disconnect

Cable

Hole in Right

End Bracket

Right Side of

End Bracket Mounting Disconnect

Hole in

Close “S” Hook

End Bracket

INSTALLATION

25

Mounting Disconnect

Handle Bracket

Tools Needed:

NOTE: See idrive® main installation and

Pencil

owners manual for idrive® parts.

Tape measure

Mark a location on the right jamb, 6

1/8” Drill Bit

feet above the floor to mount the

7/16” Socket

disconnect handle bracket.

 

Driver

Drill 1/8” pilot holes for the lag screws.

Power Drill

 

Align top of the bracket with the mark. Fasten bracket to the jamb with

(2) 1/4” x 1-1/2" lag screws.

6ft

(2) 1/4” x 1-1/2” Lag Screws

 

Disconnect

 

Handle Bracket

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer.