Setup menu list (continued)

RECORDING SETUP

The content selected under [RECORDING SETUP] is set for each mode individually.

Item

Display

 

 

 

 

Description of settings

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC FORMAT

SDI/CAM

 

Selects the recording format.

 

 

 

 

When [SYSTEM FREQ]

 

 

When [SYSTEM FREQ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is set to [59.9Hz]

 

 

is set to [50Hz]

 

 

PH 1080/60i

PH 1080/50i

 

 

PH 1080/30P

PH 1080/25P

 

 

PH 1080/24P

PH 720/50P

 

 

PH 720/60P

PH 720/25P

 

 

PH 720/30P

HA 1080/50i

 

 

PH 720/24P

HG 1080/50i

 

 

HA 1080/60i

HE 1080/50i

 

 

HG 1080/60i

 

 

 

 

 

HE 1080/60i

 

 

 

 

 

Only available in CAM mode.

 

 

 

PH 1080/24P and PH 720/24P represent native recording.

PREREC

CAM

 

Selects whether to use the PRE REC function. (Page 49)

MODE

 

 

ON OFF

 

 

 

 

 

 

When [ON] is selected, [TCG] in the [TC/UB SETUP] setup menu is set to

 

 

 

[FREE RUN].

 

 

 

AUTO REC

SDI

 

Selects whether to record and stop automatically in accordance with the signal

 

 

 

input from a camera-recorder that is connected to the HD-SDI terminal.

 

 

 

OFF:

Does not record or stop automatically.

 

 

 

TYPE1:

Records and stops automatically in accordance with the recording

 

 

 

 

 

mark in the LTC information that is added to HD-SDI.

 

 

 

TYPE2:

Records and stops automatically in accordance with the recording

 

 

 

 

 

mark in the S-VITC information that is added to HD-SDI.

 

 

 

TYPE3:

Sets when using a camera-recorder that is not manufactured by

 

 

 

 

 

Panasonic.

 

 

 

 

 

 

For details on whether to select TYPE1 or TYPE2, see “Recording formats and

 

 

 

recording marks of Panasonic camera-recorders”. (Page 85)

 

 

 

See the following web site for devices that have confirmed compatibility with TYPE3.

 

 

 

http://panasonic.biz/sav/autorec_e

 

 

 

The input and recording may not be synchronized at such times as when the

 

 

 

recording/stop interval is too short (1 second or less) or when the input signals

 

 

 

are disturbed.

 

 

 

 

 

 

When a setting other than [OFF] is selected, the recorder’s power must be

 

 

 

turned on, and the camera recorder must be connected in the recording

 

 

 

standby mode.

 

 

 

TIME STAMP

SDI/CAM

 

Sets whether date and time information is superimposed over recorded images.

 

 

 

ON:

Superimposes the information that is set in [DATE/TIME].

 

 

 

OFF:

Does not superimpose the information that is set in [DATE/TIME].

MIC ALC

SDI/CAM

 

Selects whether to automatically control the microphone level which is input from

 

 

 

the microphone.

 

 

 

 

 

 

ON OFF

 

 

 

 

 

 

Set to [ON] to reduce audio distortion at high input levels.

 

 

 

To adjust the recording level of audio signals (not related to the settings of this item),

 

 

 

press the [AUDIO MON/ADV] button while pressing the [SHIFT/EXEC] button.

INT SG

SDI/CAM

 

Switches the recording signal to the internal signal.

 

 

 

ON:

Internal color bar

 

 

 

 

 

 

OFF:

External input signal

indicates the factory default setting.

84