CONTENTS
Setup menus
USER menu | <TAPE PROTECT> |
|
|
| ||||
|
|
|
|
|
|
|
| |
No./Item |
|
|
| Description |
|
|
| |
|
| |||||||
|
| |||||||
400 | This selects the time to be taken until the unit | |||||||
| goes into the tape protection mode when it is | |||||||
STILL TIMER | left standing in the stop or search still |
| ||||||
| (JOG/SLOW/SHTL) mode. |
|
|
| ||||
| (Unit: s = second, min = minute) |
|
|
| ||||
|
| 0000 | 0.5s | <Notes> |
|
|
| |
|
| 0001 | 5s | OSTEP FWD and HALF | ||||
|
| 0002 | 10s | LOADING are provided in the | ||||
|
| 0003 | 20s | tape protection mode. Either | ||||
|
| 0004 | 30s | of these can be set for STOP | ||||
|
| 0005 | 40s | and SEARCH STILL. |
| |||
|
| 0006 | 50s OThe cumulative standby time | |||||
|
| 0007 | 1min | at the same tape position | ||||
|
| 0008 | 2min | increases when transmitting | ||||
|
|
|
| programmes | or | otherwise | ||
|
|
|
| using identical | materials | |||
|
|
|
| repeatedly. |
|
|
| |
|
|
|
| In order to protect the tape, it | ||||
|
|
|
| is | recommended | that | the | |
|
|
|
| shortest possible setting for | ||||
|
|
|
| the standby time in the same | ||||
|
|
|
| tape location is used. |
| |||
|
|
|
| OWhen a DV/DVCAM tape is | ||||
|
|
|
| used, any setting above 10 | ||||
|
|
|
| seconds will be treated as 10 | ||||
|
|
|
| seconds. |
|
|
| |
|
| |||||||
401 | When the time selected as the setup menu | |||||||
| item No. 400 (STILL TIMER) setting elapses | |||||||
SRC | while | the unit is in the search STILL | ||||||
PROTECT | (JOG/SLOW/SHTL) | mode, | the | unit | ||||
| automatically enters one of the tape | |||||||
| protection modes. This menu item is for | |||||||
| selecting which tape protection mode the unit | |||||||
| is to enter. |
|
|
|
|
| ||
|
| 0000 | STEP : STEP FWD |
|
|
| ||
|
| 0001 | HALF : HALF LOADING |
|
|
| ||
| <Note> |
|
|
|
|
|
| |
| When STEP FWD is selected, the unit | |||||||
| automatically goes into the STANDBY OFF | |||||||
| (HALF LOADING) mode when the total time for | |||||||
| which the unit is left standing in the still status | |||||||
| reaches 30 minutes (or 1 minute for a | |||||||
| DV/DVCAM tape). |
|
|
|
| |||
|
|
| ||||||
402 | This selects the drum operation in the |
| ||||||
| STANDBY OFF (HALF LOADING) mode. |
| ||||||
DRUM STDBY |
|
|
|
|
|
|
|
|
|
| 0000 | OFF : The drum stops rotating. |
| ||||
|
| 0001 | ON : The drum continues rotating. |
| ||||
|
|
|
|
|
|
|
|
|
No./Item | Description |
|
|
|
|
403 | When the time selected as the setup menu |
| item No. 400 (STILL TIMER) setting elapses |
STOP | while the unit is in the STOP mode, the unit |
PROTECT | automatically enters one of the tape |
| protection modes. This menu item is for |
| selecting which tape protection mode the unit |
| is to enter. |
| 0000 STEP : STEP FWD |
| 0001 HALF : HALF LOADING |
| <Note> |
| When STEP FWD is selected, the unit is |
| automatically transferred to the STANDBY OFF |
| (HALF LOADING) mode when the total time |
| during which it has been left standing in the |
| STOP mode reaches 30 minutes (or 1 minute for |
| a DV/DVCAM tape). |
|
|
The underlined items indicates the initial setting.
43 (E)