OPERATION

 

Item

 

Setting

 

 

 

 

 

Description of settings

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

161

CTL BGN

 

 

For setting the BEGIN point in the repeat playback mode.

 

or

 

 

Either TC or CTL is set as the counter display mode using the COUNTER button.

 

TC BGN

 

 

If no mode is set, – – :– :– : – – appears, and the tape start serves as the

 

 

 

 

BEGIN point.

 

 

 

 

 

162

END

 

 

For setting the END point in the repeat playback mode.

 

 

 

 

Either TC or CTL is set as the counter display mode using the COUNTER button.

 

 

 

 

If no mode is set, – – :– :– : – – appears, and the tape end serves as the END

 

 

 

 

point.

 

 

 

 

 

163

REPT MODE

 

 

For setting what images are to be output while the tape returns to the BEGIN point

 

 

 

 

in the repeat playback mode.

 

 

0000

FREEZE

0: The tape returns to the BEGIN point with the image played back at the END

 

 

 

 

point still frozen.

 

 

0001

BLACK

1: The tape returns to the BEGIN point while the screen remains black.

 

 

0002

SW

2: The tape returns to the BEGIN point following the setting selected by the

 

 

 

 

TAPE/EE switch.

 

 

 

 

<Note>

 

 

 

 

If the tape end is set as the END point when “0:FREEZE” is selected, the playback

 

 

 

 

image will not be frozen properly.

 

 

 

 

Set the END point to a place within the range where images are recorded.

 

 

 

 

 

180

BATTERY SEL

 

 

For setting the type of battery.

 

 

0000

NiCd12

0: 12 V-type battery

 

 

0001

NiCd13

1: 13 V-type battery

 

 

0002

NiCd14

2: 14 V-type battery

 

 

0003

S-LION

3: Setting for using the BP-L90A lithium-ion battery.

 

 

0004

I-LION

4: Setting for using the ENDURA80 lithium-ion battery.

 

 

0005

TYPE-A

5: Setting for using the battery selected by the menu item No.181 [TYPE-A NEAR]

 

 

 

 

item and No.182 [TYPE-A END] item

 

 

0006

TYPE-B

6: Setting for using the battery selected by the menu item No.183 [TYPE-B NEAR]

 

 

 

 

item and No.184 [TYPE-B END] item

 

 

 

 

 

181

TYPE-A NEAR

0000

10.6

For setting (in increments of 0.1 V) the voltage level at which the counter flashes as

 

 

:

:

warning for TYPE-A battery (selected as the menu item No.180 [BATTERY SEL]

 

 

0044

15.0

item).

 

 

 

 

<Note>

 

 

 

 

When this item has been set to a voltage level close to 15.0 V, the counter display

 

 

 

 

may flash even when an AC power source is being used.

 

 

 

 

 

182

TYPE-A END

0000

10.6

For setting (in increments of 0.1 V) the voltage level at which the TYPE-A battery

 

 

:

:

(selected as the menu item No.180 [BATTERY SEL] item) is to be automatically

 

 

0034

14.0

turned off.

 

 

 

 

 

183

TYPE-B NEAR

0000

10.6

For setting (in increments of 0.1 V) the voltage level at which the counter flashes as

 

 

:

:

warning for TYPE-B battery (selected as the menu item No.180 [BATTERY SEL]

 

 

0044

15.0

item).

 

 

 

 

<Note>

 

 

 

 

When this item has been set to a voltage level close to 15.0 V, the counter display

 

 

 

 

may flash even when an AC power source is being used.

 

 

 

 

 

184

TYPE-B END

0000

10.6

For setting (in increments of 0.1 V) the voltage level at which the TYPE-B battery

 

 

:

:

(selected as the menu item No.180 [BATTERY SEL] item) is to be automatically

 

 

0034

14.0

turned off.

 

 

 

 

 

” indicates the factory setting.