Setup menus

TIME CODE

 

Item

 

Setting

 

 

 

 

 

Description of settings

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

VITC BLANK

 

 

For setting whether to output the VITC signal at the position which is set using

 

 

 

 

menu items No.501 [VITC POS-1] and No.502 [VITC POS-2].

 

 

0000

BLANK

0: The VITC signal is not output.

 

 

0001

THRU

1: The VITC signal is output.

 

 

 

 

<Note>

 

 

 

 

This setting takes effect only with the SD output (VIDEO output and SD SDI

 

 

 

 

output).

 

 

 

 

 

501

VITC POS-1

0000

7L

For setting the position where the VITC signal is to be inserted.

 

 

:

:

<Notes>

 

 

0004

11L

O The same line as the one selected by menu item No.502 [VITC POS-2] cannot

 

 

:

:

be selected.

 

 

0015

22L

O If 59/60 is selected as the menu item No.25 [SYSTEM FREQ] setting, the

 

 

 

 

setting range is lines 10L to 16L to 20L.

 

 

 

 

O This setting takes effect only with the SD output (VIDEO output and SD SDI

 

 

 

 

output).

 

 

 

 

 

502

VITC POS-2

0000

7L

For setting the position where the VITC signal is to be inserted.

 

 

:

:

<Notes>

 

 

0006

13L

O The same line as the one selected by menu item No.501 [VITC POS-1] cannot

 

 

:

:

be selected.

 

 

0015

22L

O If 59/60 is selected as the menu item No.25 [SYSTEM FREQ] setting, the

 

 

 

 

setting range is lines 10L to 18L to 20L.

 

 

 

 

O This setting takes effect only with the SD output (VIDEO output and SD SDI

 

 

 

 

output).

 

 

 

 

 

503

TCG MODE

 

 

For setting the synchronization of the internal time code generator.

 

 

0000

REGEN

0: The time code which is read from the tape by the time code reader is used.

 

 

0001

PRE

1: The mode can be preset using the controls on the operation panel or the remote

 

 

 

 

controller.

 

 

0002

AUTO

2: REGEN or PRE is automatically selected depending on the operation mode.

 

 

 

 

Follow-on recording mode: REGEN is selected.

 

 

 

 

All other modes: PRE is selected.

 

 

 

 

 

504

RUN MODE

 

 

For setting the operation mode in which the internal time code generator runs.

 

 

0000

REC

0: The generator runs only while recording is in progress.

 

 

0001

FREE

1: The generator runs while the power is on regardless of the unit’s operation

 

 

 

 

mode.

 

 

 

 

 

505

TCG REGEN

 

 

For setting the signal to be regenerated when the TCG (time code generator) is in

 

 

 

 

the regeneration mode.

 

 

0000

TC&UB

0: Both the time code and user’s bit are regenerated.

 

 

0001

TC

1: Only the time code is regenerated.

 

 

0002

UB

2: Only the user’s bit is regenerated.

 

 

 

 

 

507

TC SOURCE

 

 

For selecting the time code to be used when an external time code is used.

 

 

0000

INT

0: The internal time code generator is used.

 

 

0001

EXT L

1: The LTC information of the TIME CODE IN connector is used.

 

 

0002

SLTC

2: The LTC information added to the serial signals which are supplied to the HD

 

 

 

 

SDI IN connector is used.

 

 

0003

SVITC

3: The VITC information added to the serial signals which are supplied to the HD

 

 

 

 

SDI IN connector is used.

 

 

 

 

<Notes>

 

 

 

 

O When a setting other than INT has been selected for this menu item, the user’s

 

 

 

 

bit of the LTC and VITC which is output during recording may be output with a

 

 

 

 

delay of 1 frame from the time code.

 

 

 

 

O When “1394” is selected as the menu item No.600 [VIDEO IN SEL] setting and

 

 

 

 

a setting other than INT is selected for TC SOURCE, the time code which is

 

 

 

 

input to the DV connector is used.

 

 

 

 

At this time, the VITC information will not be superimposed onto the video signal

 

 

 

 

output when recording is performed or the E-E mode is established. The LTC

 

 

 

 

information and VITC information are not superimposed onto the HD serial

 

 

 

 

output signals.

 

 

 

 

 

” indicates the factory setting.

41

Page 41
Image 41
Panasonic AJ-YA120AG manual Time Code