Error messages
Error No. | Error message and description | |
|
| |
| FRONT LOAD ERROR | |
| This appears when the | |
E – 51 | engaging the tape for the prescribed period of time | |
| in the start end processing operation while the tape | |
| is loading (at the | |
|
| |
|
| |
| This appears when the | |
E – 52 | take up the tape while the tape is running in the | |
| status where the total tape duration is undetected | |
| after the cassette was inserted. | |
|
| |
| WINDUP ERROR | |
| This appears when the amount of tape taken up by | |
E – 53 | the | |
supply reel while the tape is running are abnormally | ||
| ||
| different after the total tape duration has been | |
| detected. | |
|
| |
| UNLOAD ERROR | |
E – 55 | This appears when the tape has not been taken up | |
| during unloading. | |
|
| |
| ||
E – 57 | This appears when the tape start end processing | |
| operation fails to be completed. | |
|
| |
| DRUM ROTA TOO SLOW | |
E – 59 | This appears when the cylinder motor rotates | |
| abnormally slowly. | |
|
| |
| DRUM ROTA TOO FAST | |
E – 60 | This appears when the cylinder motor rotates | |
| abnormally quickly. | |
|
| |
| CAP ROTA TOO SLOW | |
E – 61 | This appears when the capstan motor rotates | |
| abnormally slowly. | |
|
| |
| S REEL TOO FAST | |
E – 64 | This appears when the supply reel motor rotates | |
| abnormally quickly. | |
|
| |
| T REEL TOO FAST | |
E – 67 | This appears when the | |
| abnormally quickly. | |
|
|
Error No. | Error message and description | |
|
| |
| T REEL TORQUE ERR | |
E – 69 | This appears when an abnormal level of torque has | |
been detected as having been applied to the | ||
| ||
| reel motor. | |
|
| |
| This appears on the front panel’s counter display | |
| when a communication error between the IF | |
E – 6A | microcomputer and front microcomputer has | |
| occurred. At this time, the superimposed display will | |
| be cleared. | |
|
| |
| S REEL TORQUE ERR | |
E – 70 | This appears when an abnormal level of torque has | |
been detected as having been applied to the supply | ||
| ||
| reel motor. | |
|
| |
| CAP TENSION ERROR | |
E – 71 | This appears when abnormal tension on the supply | |
| side has been detected in the capstan mode. | |
|
| |
| REEL TENSION ERROR | |
E – 72 | This appears when abnormal tension on the supply | |
| side has been detected in the reel mode. | |
|
| |
| REEL DIR UNMATCH | |
E – 73 | This appears when the direction of the | |
| motor has been reversed. | |
|
| |
| DRUM TORQUE ERROR | |
E – 74 | This appears when an abnormal level of torque has | |
been detected as having been applied to the | ||
| ||
| cylinder motor. | |
|
| |
|
| |
E – 78 | This appears when trouble has occurred in | |
communication between the mechanism relay board | ||
| ||
| and servo microcomputer. | |
|
| |
| BATTERY | |
E – bA | This appears when the input DC voltage has | |
dropped below the undercut voltage (approx. | ||
| ||
| 10.6 V). | |
|
|
Consult your dealer if the error message display persists even after the unit has been restarted.
50