Setup menus

INTERFACE

 

Item

 

Setting

 

 

 

 

 

Description of settings

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

202

ID SEL

 

 

For setting the ID information to be returned to the controller.

 

 

0000

OTHER

0: The ID information of the VTR other than DVCPRO is set.

 

 

0001

DVCPRO

1: The DVCPRO ID information is set.

 

 

0002

ORIG

2: Set this only when the unit is connected to a Panasonic controller (such as the

 

 

 

 

AJ-A900, optional accessory).

 

 

 

 

<Note>

 

 

 

 

Select 1 (DVCPRO) or 2 (ORIG) if “23/24,” “25(HD)” or “25(SD)” is selected as the

 

 

 

 

menu item No.25 [SYSTEM FREQ] setting.

 

 

 

 

 

TAPE PROTECT

 

Item

 

Setting

 

 

 

 

 

Description of settings

No.

Superimposed

No.

Superimposed

 

display

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

STILL TIMER

0000

0.5S

For setting the time to be taken before the unit is set in the tape protection mode

 

 

0001

5S

when it is left standing in the STOP or STILL status.

 

 

0002

10S

(Units: S = seconds, min = minutes)

 

 

0003

20S

<Note>

 

 

0004

30S

When a DV or DVCAM tape is used, any setting above 2 (10S) will result in a

 

 

0005

40S

setting time of 10 seconds.

 

 

0006

50S

 

 

 

0007

1min

 

 

 

0008

2min

 

 

 

 

 

 

401

SRC PROTECT

 

 

For setting the operation to be performed in the tape protection mode when the unit

 

 

 

 

is left standing in the STILL status.

 

 

0000

STEP

0: STEP FWD

 

 

0001

HALF

1: Standby OFF (half loading)

 

 

 

 

<Note>

 

 

 

 

If STEP FWD is selected, the unit is automatically transferred to the standby OFF

 

 

 

 

(half loading) mode when the unit is left standing in the STILL mode for a total of 30

 

 

 

 

minutes (or 1 minute for DV or DVCAM tape).

 

 

 

 

 

402

DRUM STDBY

 

 

For setting the cylinder operation in the standby OFF (half loading) mode.

 

 

0000

OFF

0: The cylinder stops rotating.

 

 

0001

ON

1: The cylinder continues to rotate.

 

 

 

 

 

403

STOP PROTECT

 

 

For setting the operation to be performed in the tape protection mode when the unit

 

 

 

 

is left standing in the STOP status.

 

 

0000

STEP

0: STEP FWD

 

 

0001

HALF

1: Standby OFF (half loading)

 

 

 

 

<Note>

 

 

 

 

When STEP FWD is selected, the unit is automatically transferred to the standby

 

 

 

 

OFF (half loading) mode when the unit is left standing in the STOP mode for a total

 

 

 

 

of 30 minutes (or 1 minute for DV or DVCAM tape).

 

 

 

 

 

” indicates the factory setting.

40

Page 40
Image 40
Panasonic AJ-YA120AG manual Interface, Tape Protect