Using SIS Commands

Simple Instruction Set (SIS) commands can be entered on your computer, using a utility such as Extron DataViewer or HyperTerminal, to find out more information about the MLC 52, to toggle display power or front panel lock state, or to reset the unit.

Host-to-Controller Communications

SIS commands consist of strings of one or more characters per field. No special characters are required to begin or end a command sequence. When the MLC determines that a command is valid, it executes the command and sends a response to the host device.

Most responses from the MLC 52 to the host end with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string.

Controller-initiated messages

When a local event such as a front panel button press takes place, the MLC 52 responds by sending a message to the host, indicating what selection was entered. No response is required from the host.

The MLC sends the following copyright message only when it first powers on.

(c) Copyright 20nn, Extron Electronics, MLC 52, Vn.nn, 60-100n-nn

where Vn.nn is the firmware version number and 60-100n-nnis the MLC 52 model number.

Error Responses

If the MLC 52 is unable to execute a command it receives because the command is invalid or contains invalid parameters, the controller returns an error response to the host. This response consists of the letter “E” followed by a number and a carriage return with a line feed. The following error response codes can be returned:

E10 – Invalid command or parameter

E14 – Not valid for this configuration

Using the Command and Response Table

The command and response table on the following pages lists valid ASCII command codes, the responses of the MLC to the host, and a description of the command function or the results of executing the command. The ASCII to Hex Conversion Table below is for use with the command and response table.