F

Transmit (Tx)

To the Display or Projector

D

Ground (Gnd)

RS-232 Port

 

F E D C B A

RS-232

Figure 11. Wiring for RS-232 Control (RS Models Only)

Extron recommends using the CTL Series Comm-Link Control System Cable, available in lengths of 500 feet (150 m) (non-plenum only) and 1000 feet (300 m) (plenum and non-plenum) for this connection (see Recommended Cables on page 62 for ordering information).

Guides for connecting and controlling specific models of display devices are available on the Extron website. See the display device user guide for the device pin assignments in order to determine which of the cables wires to connect to the MLC RS-232 pins.

Wiring for IR Control

To control display or input devices via IR commands from the MLC, you can connect Extron IR emitters to the IR Out pin of the control connector. Up to two IR emitters can be connected via this connector at one time. Wire the connector as shown in the following illustrations.

E Modulated IR D Ground

White Striped Wire Only

IR

Emitter Connect 1 or 2

 

 

IR Emitters (max.)

 

(#70-283-01).

100 Feet (30.5 m) Maximum

MLC 52

Control

Connector

F E D C B A

IR

NOTE: Place the head of each IR Emitter over or directly adjacent to the IR receiver for the controlled device.

For the IR Emitter Only

E Demodulated IR

D Ground

MLC 52

Control

Connector

F E D C B A

To the Wired Remote Port of the Projector

(Connector type and pin configurations may vary depending on the projector model.)

IR

For a Wired Projector

Remote Port

Figure 12. Wiring the Control Connector for IR

MLC 52 MediaLink Controllers • Installation and Configuration

13

Page 19
Image 19
Extron electronic MLC 52 manual Wiring for IR Control