Panasonic AK-HC1800N operating instructions  Tally output connector Tally OUT

Models: AK-HC1800N

1 70
Download 70 pages 39.24 Kb
Page 12
Image 12

Major operating controls and their functions

Tally output connector [TALLY OUT]

The R tally and G tally signals are output from this connector.

Pin No.

Signal

1

GND

 

 

2

R_TALLY_OUT

 

 

3

G_TALLY_OUT

 

 

4

+12 V (500 mA Max)

IRIS connector [IRIS]

Used to connect the IRIS control cables of the lens.

Pin No.

Signal

Pin No.

Signal

1

Return control

7

Iris follow

2

VTR-S/S

8

Iris auto selection

3

UNREG GND

9

4

Iris manual selection

10

Zoom position information

5

Iris control

11

Focus position information

 

 

 

 

6

UNREG 12 V

12

NC

Zoom/Focus connector [ZOOM/FOCUS]

Used to connect the zoom/focus control cables of lens.

Pin No.

Signal

Pin No.

Signal

1

Focus control selection

7

COM

 

 

 

 

2

Zoom control selection

8

Focus control

3

GND

9

Zoom control

4

Forcible iris closing

10

Iris control selection

5

Iris control

11

COM +Voltage

6

+Voltage

12

COM –Voltage

Optional card slot

Slot for inserting an optional card.

Note

This product does not support the optional boards (AK-HHD1500G and AKHDC1500G).

- 12 -

Page 12
Image 12
Panasonic AK-HC1800N operating instructions  Tally output connector Tally OUT