4. Specifications

Control I/O

COM

 

Used to control an external device

D-sub, 9-pin, female

 

 

 

RS-422 control connector

 

 

 

 

Communication format (selected using a menu)

 

 

 

 

pp Mode: 1 (default setting)

 

 

 

 

Baud rate

: 9600 bps

 

 

 

 

Character length: 8 bit

 

 

 

 

Parity

: None

 

 

 

 

Stop bit

: 1 bit

 

 

 

 

Flow control

: None

 

 

 

 

pp Mode: 2

 

 

 

 

 

Baud rate

: 38400 bps

 

 

 

 

Character length: 8 bit

 

 

 

 

Parity

: Odd

 

 

 

 

Stop bit

: 1 bit

 

 

 

 

Flow control

: None

 

 

 

 

pp Mode: 3

 

 

 

 

 

Baud rate

: 38400 bps

 

 

 

 

Character length: 8 bit

 

 

 

 

Parity

: None

 

 

 

 

Stop bit

: 1 bit

 

 

 

 

Flow control

: None

 

 

TALLY/GPI 1

 

Input:

 

D-sub, 15-pin,

 

TALLY/GPI 2

 

8 inputs, general-purpose,

female (2)

 

 

 

photocoupler sensing

 

 

 

 

Output:

 

 

 

 

 

19 outputs; selected from R/G tally,

 

 

 

 

general-purpose

 

 

 

 

 

Alarm:

 

 

 

 

 

1 output, open collector output

 

 

 

 

(negative logic)

 

 

Other

BOOT switch [SV/NM (service/normal)] (for maintenance purposes)

 

 

Normally, this switch is used as the “NM” position.

 

Ambient operating

0 °C to 40 °C (32 °F to 104 °F)

 

 

temperature

 

 

 

 

 

Humidity

10 % to 90 % (no condensation)

 

 

Dimensions

440 mm 158 mm 361 mm (17-5/16 inches 6-7/32 inches 14-7/32 inches)

(W H D)

[excluding protrusions]

 

 

 

Mass

Approx. 6.2 kg (13.669 lb)

 

 

 

[excluding accessory parts when no options have been installed]

 

 

Approx. 6.6 kg (14.550 lb)

 

 

 

[excluding accessory parts when all the possible options have been installed]

 

 

 

 

 

 

37