$Connecting the base connector panel

51394 connector

This is for controlling the convertible camera, in which an IEEE 1394 card (AW-PB310), etc. has been installed, and the pan-tilt head.

As the connecting cable, use an IEEE 1394 cable.

 

 

Pin No.

Signal

6

5

 

 

1

DC 12V

4

3

2

1

2

GND

 

 

 

 

 

 

 

 

3

TPB 2

 

 

4

TPB

 

 

 

 

 

 

5

TPA 2

 

 

6

TPA

 

 

 

 

6CONTROL IN IP/RP connector

This is for camera/pan-tilt head control signals.

Connect this to the CONTROL OUT TO PAN/TILT HEAD connector on the multi- function controller (AW-RP605) or to a PC, etc. Use a 10BaseT straight cable (UTP category 5) for the connecting cable.

<Note>

To control the camera and pan-tilt head directly from a PC, etc., first convert from RS-232C to RS-422.

7Y/VIDEO OUT connector

This is for camera video signal output. Connect this to the VIDEO/Y IN connector on the multi-function controller (AW-RP605) or to a monitor, etc.

Video signals will be output from this connector when a convertible camera is used as a standard accessory.

Y signals can be output when an RGB card (AW-PB302) is installed in the convertible camera for use.

Use a coaxial cable (BELDEN 8281) for the connecting cable.

8Pr/SDI OUT connector

This is for camera video signal output. Connect this to the Pr IN connector on the multi-function controller (AW- RP605), etc. or to a monitor, etc.

Pr signals can be output when an RGB card (AW-PB302), etc. is installed in the convertible camera for use.

Alternatively, SDI signals can be output when an SDI card (AW-PB304), etc. is installed in the convertible camera for use.

Use a coaxial cable (BELDEN 8281) for the connecting cable.

9Pb OUT connector

This is for camera video signal output. Connect this to the Pb IN connector on the multi-function controller (AW-RP605, etc.) or to a monitor, etc.

Install an RGB card (AW-PB302), etc. in the convertible camera for use.

Use a coaxial cable (BELDEN 8281) for the connecting cable.

:G/L IN connector

This is for genlock signal input.

Connect this to the G/L OUT connector on the multi-function controller (AW- RP605), etc.

Use a coaxial cable (BELDEN 8281) for the connecting cable.