Black level (master pedestal) adjustment

When performing the operations using the controller

When the AWRP655 is connected:

1Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2Turn the [FOCUS/IRIS] dial to stop down the lens iris.

3Press the [R/B GAIN/PED] button several times so that the “PEDESTAL TOTAL” item is displayed on the LCD panel.

4Turn the jog dial (main) and adjust the black level to 5 IRE (0.035 V).

5If necessary, adjust the iris automatically.

Press the [IRIS] button several times to turn on its lamp.

When the AWRP555 is connected:

1Press the [IRIS] button several times to turn off its lamp.

Set the iris to the manual ([MANU]) mode.

2Turn the [LEVEL] dial of [IRIS] to stop down the lens iris.

3Follow the operation steps in “Basic operations” (page 36), and use the menu to perform the adjustment.

When the AWRP50 is connected:

Refer to the Operating Instructions of the controller.