IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

Pay close attention to all warning and caution notices given in this manual.

This symbol refers to a hazard or unsafe practice which can

WARNING result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can

CAUTION result in personal injury or prod- uct or property damage.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improp- er installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

WARNING When Wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

‡'RQRWVXSSO\SRZHUWRWKHXQLWXQWLODOOZLULQJDQGWXELQJ are completed or reconnected and checked.

‡+LJKO\GDQJHURXVHOHFWULFDOYROWDJHVDUHXVHGLQWKLV system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

‡*URXQGWKHXQLW following local electrical codes.

‡&RQQHFWDOOZLULQJWLJKWO\/RRVHZLULQJPD\FDXVHRYHU heating at connection points and a possible fire hazard.

‡7RSUHYHQWSRVVLEOHKD]DUGVIURPLQVXODWLRQIDLOXUH

the unit must be grounded.

When Transporting

Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin alu- minum fins on the air conditioner can cut your fingers.

When Installing…

Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.

…In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support.

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

 

 

 

Keep the fire alarm and the air

 

 

 

 

 

 

outlet at least 1.5 m away from

 

CAUTION

 

 

 

the unit.

 

 

 

 

 

 

 

When Connecting Refrigerant Tubing

‡ :KHQSHUIRUPLQJpiping work

 

do not mix air except for speci-

 

fied refrigerant (R410A) in

 

refrigeration cycle. It causes

 

capacity down, and risk of

 

explosion and injury due to

 

high tension inside the refrige-

WARNING

rant cycle.

‡ 5HIULJHUDQWJDVOHDNDJHPD\

 

 

cause fire.

‡'RQRWDGGRUUHSODFHUHIULJHUDQW other than specified type.

It may cause product damage, burst and injury etc.

‡9HQWLODWHWKHURRPZHOOLQWKHHYHQWWKDWUHIULJHUDQW gas leaks during the installation. Be careful not to allow contact of the refrigerant gas with a flame as this will cause the generation of poisonous gas.

‡'RQRWDGGDQ\UHIULJHUDQWDLURUVXEVWDQFHLQWRWKH refrigeration circuit other than the designated refrigerant (R410A). Adding anything other than the specified refrig- erant may cause the pressure to rise excessively in the refrigeration circuit, rupturing the circuit and causing injury or damage.

‡8VHDOOQHZWXELQJDQGIODUHQXWVWRPDNHWKHWXELQJFRQ nections. Using any previous parts (from R22-based sys- tems) may result in damage to the equipment, and may lead to the refrigeration circuit rupturing, causing a seri- ous accident.

2

Page 80
Image 80
Panasonic CU-3KE19NBU, CS-MKE9NB4U, CU-4KE31NBU, CU-4KE24NBU, CS-MKE12NB4U, CS-KE18NB4UW, CZ-18BT1U Please Read Before Starting

CZ-18BT1U, CS-KE18NB4UW, CS-MKE12NB4U, CU-3KE19NBU, CU-4KE24NBU specifications

The Panasonic CS-KE18NB4UW and CU-KE12NK1, along with the CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU, represent a suite of advanced air conditioning solutions built with cutting-edge technologies designed to provide optimal comfort, energy efficiency, and air quality in various settings.

One of the standout features of this lineup is the inverter technology. Inverter air conditioners adjust the compressor speed to maintain the desired temperature efficiently. This leads to significant energy savings compared to traditional air conditioners, which tend to frequently cycle on and off, consuming more power. By continuously regulating the temperature, the Panasonic units not only save electricity but also prolong the lifespan of the compressor.

Another noteworthy characteristic is the nanoe™ technology integrated into some of these models. Nanoe™ technology uses hydroxyl radicals to purify the air, minimizing harmful bacteria and allergens. This makes the Panasonic units particularly suitable for users with allergies or respiratory issues, providing a cleaner and healthier indoor environment.

In terms of design, these models are sleek and compact, allowing them to fit seamlessly into any room decor, whether in a home, office, or commercial space. The quiet operation is another advantage, making them ideal for bedrooms and study areas where minimal noise is essential.

Furthermore, the CS-KE18NB4UW and CU-KE12NK1 offer a range of powerful cooling and heating capacities, making them versatile solutions for various climate conditions. The cold climate performance ensures consistent heating in colder regions, while the robust cooling capabilities make them perfect for hot summer months.

The user-friendly features include a smart remote control system, allowing users to adjust settings with ease from a distance. Some models are equipped with Wi-Fi capability, enabling integration with smart home systems for enhanced control and programmability.

In conclusion, the Panasonic CS-KE18NB4UW, CU-KE12NK1, CS-KE12NB41, CZ-18BT1U, and CU-KE18NKU air conditioning units exemplify innovation and efficiency. With their inverter technology, air purification features, compact designs, and smart functionalities, they stand out as ideal choices for maintaining comfortable and healthy indoor environments throughout the year.