Panasonic CS-MKE12NB4U INSTALLATION INSTRUCTIONS Wired Remote Controller, Installation location

Models: CZ-18BT1U CS-KE18NB4UW CS-MKE12NB4U CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU CS-MKE9NB4U

1 114
Download 114 pages 38.6 Kb
Page 109
Image 109
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Wired Remote Controller

IMPORTANT

‡ In order to install this wired remote controller onto a wall-mounted model, the connection kit

 

(CZ-RC515U or CZ-RC515UA), which must be purchased separately, is required.

‡Once the wired remote controller is connected, the wireless remote controller cannot be used.

Parts supplied with the remote controller

See Table 1.

Remote controller installation guidelines

Installation location

‡Mount the remote controller 3.3 to 4.9 ft. (1 to 1.5 meters) off the floor where it can sense the average temperature of the room.

‡Do not mount the remote controller in a place exposed to direct sunlight or where it is exposed to outside air such as near a window.

‡Do not mount the remote controller behind a curtain or other object so that it is separated from the air circula- tion of the room.

‡Mount the remote controller inside the room being air conditioned.

Switching the room temperature sensor

Table 1

Parts

 

Figure

Q'ty

Parts

Figure

Q'ty

Wired

 

 

 

 

 

26.2 ft. (8m)

 

 

 

 

 

Wire

 

 

remote

 

 

 

1

 

1

 

 

 

harness

 

controller

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine

5/32

15/16"

 

Instruction

 

 

(4

25mm)

2

 

1

screws

 

 

 

manual

 

 

 

 

 

 

 

 

5/32

15/16"

 

 

 

 

Tapping

(4

25mm)

2

Installation

 

1

screws

 

 

 

Instructions

 

 

 

 

 

 

 

Spacers

2

Room temperature sensors are separately incorporated in both the indoor unit and the remote controller. Either sensor can be used to sense the room temperature. The indoor unit sensor is usually used.

If you wish the remote controller to sense the room temperature, press the SENSOR button with a ballpoint pen or tool with a small tip. (Refer to Fig. 9 on page 4 to locate the SENSOR button.)

How to install the remote controller

IMPORTANT

‡The remote controller is set to “Cool/Dry/Heat model” at

the time of shipment from the factory. If the purchased air conditioner is a COOL/DRY model, follow the instructions on the label and change the switch on the reverse side of the remote controller unit to “Cool/Dry model”. (Fig. 1)

‡ The remote controller is also set to “Single” at the time of shipment from the factory. For multiple use, set the switch on the reverse side of the remote controller unit to “Multi”. (Fig. 1)

‡ After all work is completed, if any switches have been changed, then be sure to press the ACL (Reset) button. (Refer to Fig. 9 on page 4 to locate the ACL (Reset) but- ton.)

Fig. 1

85264190592000

2011

CV6233187884

Page 109
Image 109
Panasonic CS-MKE12NB4U INSTALLATION INSTRUCTIONS Wired Remote Controller, Parts supplied with the remote controller, Table