Panasonic CU-4KE24NBU Special Remarks, Setting The Timer, ‘‘DRY’’ Operation, Heating Operation

Models: CZ-18BT1U CS-KE18NB4UW CS-MKE12NB4U CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU CS-MKE9NB4U

1 114
Download 114 pages 38.6 Kb
Page 51
Image 51
 SPECIAL REMARKS

‘‘DRY’’ (  ) Operation SPECIAL REMARKS How it works?

‘‘DRY’’ ( Heating ( ) Operation ) Operation

How it works?

Once the room temperature reaches the level that was set, the unit’s operation frequency is changed automatically.

During DRY operation, the fan speed automatically runs at lower speed for providing a comfortable breeze.

‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or less.

Heating (Heating performance ) Operation

Heating performance

Because this air conditioner heats a room by drawing in the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance together with it.

Defrosting

When the outdoor temperature is low, frost or ice may form on the heat exchanger coil, reducing heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan on the indoor unit stops and the OPERATION lamp lights red and orange alternately until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms.)

Cold draft prevention

For several minutes after the start of heating operation, the indoor fan runs at a lower speed until the indoor heat exchanger coil has warmed up sufficiently. However, the fan may remain stopped when the room temperature is low. This is because the COLD DRAFT PREVENTION SYSTEM is in operation.

Cooling (Defrosting) operation

Sometimes the indoor unit may not get to the set fan speed such as LOW under cool operation at very low outdoor temperatures due to the indoor unit being protected from ice or frost.

Power failure during operation

In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically in approximately

15 minutes by the remote controller.

Clicking Sound

Clicking sound is heard from the air conditioner

In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear.

Remote Controller

The remote controller sends the setting condition to the air conditioner regularly at five minute intervals.

Cold draft prevention SETTING THE TIMER Cooling () operation

NOTE

In the descriptions below, the following settings are used for the temperature and time indicator selector button on the bottom front section of the remote controller.

Temperature: °F

Time: AM, PM

1. How to set the present time

(Example) To set to 10:30 pm.

 

Operation

Indication

 

 

 

1.

Press the CLOCK button

The time indication alone

 

once if the time indicator is

flashes.

 

not flashing.

 

2.

Press the Advance, Return

The time can be set in 1-minute

 

( , ) button until PM 10:30

increments. Holding down the

 

is displayed.

button advances the time rapidly

 

 

in 10-minute increments.

3.

Press the CLOCK button

This completes the setting of the

 

again.

current time.

 

 

 

11

Page 51
Image 51
Panasonic CU-4KE24NBU Special Remarks, Setting The Timer, ‘‘DRY’’ Operation, Heating Operation, Cooling operation