Panasonic CU-4KE24NBU, CS-MKE9NB4U, CU-4KE31NBU, CZ-18BT1U Remove the indoor air temperature sensor

Models: CZ-18BT1U CS-KE18NB4UW CS-MKE12NB4U CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU CS-MKE9NB4U

1 114
Download 114 pages 38.6 Kb
Page 23
Image 23
6-1-4. Remove the indoor air temperature sensor.

6-1-4. Remove the indoor air temperature sensor.

(1)Disconnect the connector CN08 (ROOM 2P) in the control box and remove the indoor air temperature sensor. (Fig. 10)

Indoor air temperature sensor

CN08

Fig.10

6-1-5. Remove the power box and control box.

(1)Remove a screw and remove the terminal cover. (Fig. 11)

(2)Remove the 2 screws and remove the power box cover. (Fig. 11)

(3)Disconnect the power lines (No. 1 and No. 2) / signal line (No. 3) and ground cable from the terminals in the power box. (Fig. 12)

Terminal cover

Screw

Screw

Power box cover

Fig.11

1Fig.106-1-5. Remove the power box and control box.Fig.11Fig.12 2 Manual backgroundManual background 3

Ground cable

Terminal

Power lines / Signal line

Fig.12

23

Page 23
Image 23
Panasonic CU-4KE24NBU, CS-MKE9NB4U Remove the indoor air temperature sensor, Remove the power box and control box