Panasonic CU-2E18NBU service manual šMulti split combination possibility, Outdoor Unit

Models: CU-2E18NBU

1 57
Download 57 pages 29.38 Kb
Page 6
Image 6
šMulti split combination possibility:

 

Item

Unit

 

OUTDOOR UNIT

 

 

 

 

 

 

 

Air Volume

High

m3/min (ft3/min)

 

37.2 (1313)

Refrigerant Control Device

 

 

 

 

Expansion Valve

 

 

 

 

 

 

 

Refrigerant Oil

 

 

 

 

FV50S

 

 

 

 

 

 

 

Refrigerant (R410A)

 

 

g (oz)

 

1.92k (67.8)

 

 

 

 

 

 

 

 

 

 

 

Dry Bulb

 

Wet Bulb

 

 

 

 

 

 

 

 

Cooling

Maximum

°C (°F)

32 (89.6)

 

23 (73.4)

 

 

 

 

 

 

Indoor Operation Range

Minimum

°C (°F)

16 (60.8)

 

11 (51.8)

 

 

 

 

 

 

 

 

Heating

Maximum

°C (°F)

30 (86.0)

 

 

 

 

 

 

 

 

 

 

Minimum

°C (°F)

16 (60.8)

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Maximum

°C (°F)

43 (109.4)

 

26 (78.8)

 

 

 

 

 

 

Outdoor Operation Range

Minimum

°C (°F)

16 (60.8)

 

11 (51.8)

 

 

 

 

 

 

 

 

Heating

Maximum

°C (°F)

24 (75.2)

 

18 (64.4)

 

 

 

 

 

 

 

 

 

Minimum

°C (°F)

-15 (5.0)

 

-16 (3.2)

 

 

 

 

 

 

 

 

 

 

Note

šSpecifications are subject to change without notice for further improvement.

šMulti split combination possibility:

oA single outdoor unit enables air conditioning of up to two separate rooms for CU-2E18NBU.

Wall

2.8 kW

3.2 kW

 

 

 

Capacity range of connectable indoor units

Length

1 room maximum pipe length (m (ft))

Allowable elevation (m (ft))

 

Piping

Total allowable pipe length (m (ft))

Total pipe length for maximum chargeless length (m (ft))

 

 

Additional gas amount over chargeless length (g/m (oz/ft))

 

 

 

Outdoor Unit

 

CU-2E18NBU

 

A

 

B

 

 

CS-E9NKUAW

 

CS-E12NKUAW

 

From 5.6 kW to 6.4 kW

25 (82.0)

15 (49.2)

50 (164.0)

20 (65.6)

20 (0.2)

Note: “” : Available

Remarks for CU-2E18NBU

1.At least two indoor units must be connected.

2.The total nominal cooling capacity of indoor untis that will be connected to outdoor unit must be within connectable capacity range of indoor unit.

(as shown in the table above)

Example: The indoor units’ combination below is possible to connect to CU-2E18NBU. (Total nominal capacity of indoor units is between

5.6 kW to 6.4 kW)

1)Two CS-E9NKUAW only. (Total nominal cooling capacity is 5.6 kW)

2)One CS-E9NKUAW and one CS-E12NKUAW. (Total nominal cooling capacity is 6.0 kW)

šSpecifications are subject to change without notice for further improvement.

6