13.5 Cooling overload control (Cool)

13.5 Cooling overload control (Cool)

šThis control detect outdoor pipe temperature and perform the compressor frequency restriction during cooling operation.

13.6 Heating overload control (Heat)

šThis control detect indoor pipe temperature and perform the compressor frequency restriction during heating operation.

šThis control detect outdoor ambient temperature and perform the fan speed adjustment during heating operation.

13.7 Extreme Low Temperature Compressor low pressure protection control (Heat)

šThis control is to prevent low pressure drops too low during extremely low outdoor ambient temperature to improve the compressor reliability.

šDuring heating operation, when outdoor ambient temperature is in Zone 1, this control will be activated. Compressor frequency restriction will be based on outdoor piping temperature.