12.Simultaneous Operation Control
1Operation modes which can be selected using the remote control unit: Automatic, Cooling, Soft Dry, Heating,
2Types of operations modes which can be performed simultaneously
o Cooling operation and cooling, Soft Dry or
o Heating operation and heating operation
3Types of operation modes which cannot be performed simultaneously
o While a cooling operation is in progress, a heating operation cannot be performed by an indoor unit in another room.
In the room where the operation button for cooling was pressed first, the operation is continued. In the room where the operation button for heating was pressed afterward, the operation lamp of the indoor unit blinks, where the attempt is made to establish the heating operation. Its fan is stopped, and the air does not discharged.
o While a heating operation is in progress, a cooling operation cannot be performed by an indoor unit in another room.
In the room where the operation button for heating was pressed first, the operation is continued. In the room where the operation button for cooling was pressed afterward, the operation lamp of the indoor unit blinks, where the attempt is made to establish the cooling operation. Its fan is stopped, and the air does not discharged.
4Operation mode priority control
o The operation mode designated first by the indoor unit has priority.
o If the priority indoor unit stops operation or initiates the
22