Manuals
/
Panasonic
/
Household Appliance
/
Air Conditioner
Panasonic
CU-2E18NBU service manual Wiring Connection Diagram
Models:
CU-2E18NBU
1
11
57
57
Download
57 pages
29.38 Kb
8
9
10
11
12
13
14
15
<
>
Troubleshooting
Specifications
Operation Characteristics
Install
Parts list
Refrigeration Cycle Diagram
Exploded View and Replacement Parts
Dimension
14.1.3Wiring Error check
Disassembly and Assembly Instructions
Page 11
Image 11
6. Wiring Connection Diagram
11
Page 10
Page 12
Page 11
Image 11
Page 10
Page 12
Contents
Outdoor Unit CU-2E18NBU
TABLE OF CONTENTS
List
16. Disassembly and Assembly Instructions
18. Exploded View and Replacement Parts
1. Safety Precautions
7.Power supply connection to the air conditioner
OUTDOOR UNIT
2. Specifications
2.1CU-2E18NBU
Unit
OUTDOOR UNIT
Multi split combination possibility
Unit
Indoor unit combination
3. Dimensions
4. Refrigeration Cycle Diagram
5. Block Diagram
6. Wiring Connection Diagram
7. Electronic Circuit Diagram
8.1Main Printed Circuit Board
8. Printed Circuit Board
8.3Display Printed Circuit Board
8.2Noise Filter Printed Circuit Board
68.6 - 65.6 ft x 0.2 oz/ft = 0.6 oz
9. Installation Information
9.1Check Points
10.1 Select The Best Location
10. Installation Instruction
Gas Leak Checking
10.2 Install The Outdoor Unit
10.3 Connect the Piping
Outdoor Unit Installation Guidelines
CUTTING AND FLARING THE PIPING
10.4 Evacuation of the Equipment
10.6 Heat Insulation
10.5 Connect The Cable To The Outdoor Unit
11.1 Cooling Operation
11. Operation Control
11.2.1Outdoor fan control
11.2 Heating Operation
11.2.2Powerful Operation
11.2.3Powerful Operation
12.Simultaneous Operation Control
13.2 Dew Prevention control Cool
13. Protection Control
13.1 Freeze Prevention control Cool
13.6 Heating overload control Heat
13.5 Cooling overload control Cool
13.10 30 seconds Force Operation
13.9 Time Delay Safety Control Restart Control
13.12 IPM power transistor Protection Control
13.8 Deice Control
13.15 Valve close detection control
14.1 CU-2E18NBU
14. Servicing Mode
14.1.6Cooling only function
14.1.3Wiring Error check
14.1.4Power Save Mode
14.1.5Mode priority function
15.1 Self Diagnosis Function
15. Troubleshooting Guide
Page
Page
16.1 Outdoor Unit Removal Procedure
16. Disassembly and Assembly Instructions
16.1.4Removing the Propeller Fan and Fan Motor
16.1.3Removing the Control P.C. Board
Page
Cooling Characteristic
17. Technical Data
17.1 Operation Characteristics
Compressor Freq Fc
Cooling Characteristic
Piping Length Characteristic Cooling
Condition Room temperature 81F DBT, 66F WBT Operation condition High fan speed Outdoor temperature 95F DBT Compressor Freq Fc
Piping Length Characteristic Cooling
Heating Characteristic
Condition Room temperature 68F DBT Operation condition High fan speed Piping Length 24.6ft Compressor Freq Fh
Heating Characteristic
Piping Length Characteristic Heating
Condition Room temperature 68F DBT Operation condition High fan speed Outdoor temperature 47F DBT, 43F WBT Compressor Freq Fh
Piping Length Characteristic Heating
Compressor Freq Fc
Cooling Characteristic
17.1.2Two Indoor Unit Operation
Compressor Freq Fc
Cooling Characteristic
Compressor Freq Fc
Cooling Characteristic
Condition Room temperature 81F DBT, 66F WBT Operation condition High fan speed Outdoor temperature 95F DBT Compressor Freq Fc
Piping Length Characteristic Cooling
Condition Room temperature 81F DBT, 66F WBT Operation condition High fan speed Outdoor temperature 95F DBT Compressor Freq Fc
Piping Length Characteristic Cooling
Condition Room temperature 81F DBT, 66F WBT Operation condition High fan speed Outdoor temperature 95F DBT Compressor Freq Fc
Piping Length Characteristic Cooling
Condition Room temperature 68F DBT Operation condition High fan speed Piping Length 24.6ft Compressor Freq Fh
Heating Characteristic
Condition Room temperature 68F DBT Operation condition High fan speed Piping Length 24.6ft Compressor Freq Fh
Heating Characteristic
Condition Room temperature 68F DBT Operation condition High fan speed Piping Length 24.6ft Compressor Freq Fh
Heating Characteristic
Condition Room temperature 68F DBT Operation condition High fan speed Outdoor temperature 47F DBT, 43F WBT Compressor Freq Fh
Piping Length Characteristic Heating
Condition Room temperature 68F DBT Operation condition High fan speed Outdoor temperature 47F DBT, 43F WBT Compressor Freq Fh
Piping Length Characteristic Heating
Condition Room temperature 68F DBT Operation condition High fan speed Outdoor temperature 47F DBT, 43F WBT Compressor Freq Fh
Piping Length Characteristic Heating
18. Exploded View and Replacement Parts List
CU-2E18NBU
REF. NO
DESCRIPTION & NAME
Q’TY