< Heating Capacity >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

28,400 BTU/h

 

AIR FLOW RATE:

 

918 CFM

 

 

OUTDOOR

 

 

 

 

 

INDOOR

 

 

 

 

ENT. TEMP. o F (o C)

 

 

 

 

AMBIENT TEMP. o F (o C)

 

 

 

 

 

 

WB

 

 

 

60

65

 

70

75

 

80

 

 

 

 

 

 

 

(15.6)

(18.3)

 

(21.1)

(23.9)

 

(26.7)

 

 

0

(-17.8)

 

TH

 

16,030

16,040

 

16,050

16,040

 

16,020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

(-16.1)

 

TH

 

16,550

16,560

 

16,570

16,560

 

16,540

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

(-13.3)

 

TH

 

17,790

17,810

 

17,820

17,810

 

17,790

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

(-10.6)

 

TH

 

19,080

19,100

 

19,110

19,100

 

19,090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

(-7.8)

 

TH

 

20,500

20,520

 

20,530

20,530

 

20,510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

(-5.0)

 

TH

 

21,990

22,010

 

22,020

22,010

 

22,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

(-2.2)

 

TH

 

23,530

23,560

 

23,570

23,560

 

23,540

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

(0.6)

 

TH

 

25,130

25,150

 

25,160

25,150

 

25,130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

(3.3)

 

TH

 

26,700

26,730

 

26,740

26,730

 

26,700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

(6.1)

 

TH

 

28,360

28,390

 

#

28,400

28,390

 

28,360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

(8.9)

 

TH

 

30,050

30,070

 

30,080

30,070

 

30,040

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53

(11.7)

 

TH

 

31,740

31,770

 

31,780

31,770

 

31,530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

(14.4)

 

TH

 

33,370

33,400

 

33,410

33,400

 

32,030

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

(17.2)

 

TH

 

35,050

35,080

 

35,090

35,070

 

32,450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

(18.3)

 

TH

 

35,700

35,730

 

35,740

35,400

 

32,570

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH : Total Heating Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB

:Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB

2.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.