58
VQT1H62
Recording
3Press the cursor button to set

and then press the MENU button

to finish the setting.

DMicrophone input level meter
Microphone input level meter is displayed on
the screen.
To return to automatic setting
Press the MENU button, then select [VIDEO] #
[MIC LEVEL] # [AUTO], and press the cursor
button.
Adjust the gain value so that the last 2 bars of
the microphone input level on the center of the
screen are not red. (Otherwise, the sound is
distorted.) Select a lower setting for gain value
or set [MICLEVEL] to [AUTO].
The microphone input level meter displays the
microphone input level for the built-in
microphone with the larger volume.
When [ZOOM MIC] is [ON], the volume will be
different depending on the zoom rate. Set
[ZOOM MIC] to [OFF] or set the microphone
input level after adjusting the zoom rate.
(l49)
Parts where white saturation (color saturation) is
likely to occur (extremely brightly lit or shiny
parts) are displayed with diagonal lines (zebra
pattern).
¬Rotate the mode dial to select .

Press the MENU button, then select

[ADVANCED] # [ZEBRA] # [ON]

and press the cursor button.

AZebra pattern
You can record an image with little white
saturation if you manually adjust the shutter
speed or brightness (iris/gain) (l63).
To cancel the zebra display
Press the MENU button, then select
[ADVANCED] # [ZEBRA] # [OFF] and press
the cursor button.
The zebra pattern does not appear on the
images actually recorded.
This unit displays a 7 color bar which is useful for
adjusting the picture quality of the TV or the
external monitor.
¬Rotate the mode dial to select .

Press the MENU button, then select

[ADVANCED] # [COLOR BAR] #

[ON] and press the cursor button.
To cancel the color bar
Press the MENU button, then select
[ADVANCED] # [COLORBAR] # [OFF] and
press the cursor button.

Zebra display

Displays portions of the image that
may be overexposed.
D

Color bar

This is for displaying a color bar to
check the color tone.
A
VQT1H62_ENG_PP.book 58 ページ 2007年7月17日 火曜日 午後5時44分