Network
JJError information pageIf [Error (Detail)] is displayed in the
•Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
Settings
OK: | Normal operation |
FAILED : Occurrence of trouble | |
WARNING: Warning |
| When [FAILED] has appeared for an item | |
|
| |
Parameter | Description | |
MAIN CPU BUS | Trouble has occurred in the microcomputer circuitry. Consult your dealer. | |
FAN | Trouble has occurred in the fan or its drive circuit. Consult your dealer. | |
| Intake air temperature is high. It could be because it is used in an environment of high | |
INTAKE AIR TEMPERATURE | temperature such as close to a heating device, etc., the air intake is blocked, or the air | |
| filter is clogged. | |
|
| |
AROUND LAMP TEMPERATURE | The temperature around the lamp is too high. Exhaust may be blocked, or [Fan control] | |
mode may be set wrong. See [Fan control] of the Functional Manual. (Æpage 66) | ||
| ||
OPTICS MODULE TEMPERATURE | Optics module temperature is high. The exhaust air port maybe blocked or the air filter | |
is clogged. | ||
| ||
LAMP REMAIN TIME | The lamp runtime has exceeded the prescribed cumulative time, and it is now time to | |
replace the lamp. | ||
| ||
|
| |
LAMP STATUS | The lamp has failed to light. | |
Wait a short while for the lamp to cool off, and then turn on the power. | ||
| ||
Trouble has occurred in the contrast shutter circuitry. Consult your dealer. | ||
SHUTTER | There is a problem with shutter. | |
AIR FILTER | There is a problem with the air filter unit. | |
FILTER UNIT | The air filter unit is not installed. |
Displays the current configuration information of the network.
Displays the configuration details of wired LAN.
78 - ENGLISH