CONNECTIONS

Precautions

The following connections should be made by qualified service personnel or system installers in accordance with all local codes.

Switch the 24 V AC power source off before installation and connection.

24 V AC cable for Heater

24 V AC

Data port

Video output

Alarm in

Alarm out

24 V AC cable for Camera

RS485 cable

Coaxial cable

To VIDEO IN

 

(CAMERA IN)

BNC plug

BNC plug

 

To sensors

 

To indicators

The coaxial cable length (RG-6/U, 5C-2V) for the connection is up to

1 200 meters (4 000 ft.)

Note: When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing opera- tion).

• 24 V AC Power Supply Connection

Recommended wire gauge sizes for 24 V AC line

Copper wire size

#24

#22

#20

#18

(AWG)

 

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

 

 

 

 

 

 

Length

(m)

20

30

45

75

of cable

 

 

 

 

 

(ft)

65

100

160

260

(approx.)

 

 

 

 

 

 

Accessory Connector Information

Pin no.

Power source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

24 V AC LIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

24 V AC NEUTRAL

 

4

 

 

3

3

Ground

 

 

 

 

 

 

 

 

 

2

 

1

4

Not use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

How to Assemble the Cable with the Accessory Connector

Strip back the cable jacket approx. 3 mm (0.1 inch) and separate the individual conductors.

 

.

 

 

Approx.

 

 

3 mm (0.1 inch)

Wire

 

3 mm (0.1 inch)

Up

A

 

Contact

Insert

 

 

 

the wire until A position

 

Insert the wire until A position

 

and clamp the contacts.

 

and clamp the contacts.

Prepare the individual conductors for clamping. Use MOLEX band tool part number 57027-5000 (for UL- Style Cable UL1015) or 57026-5000 (for UL-Style UL1007) for clamping the contacts.

After clamping the contacts, push them into the proper holes in the accessory connector of this camera until they snap in place.

Up

Wire

Contact

CAUTIONS

Shrinking the cable-entry seal is a one-time proce- dure. Do not shrink the cable-entry seal until it has been ascertained that the unit is functioning.

CONNECT THIS TO 24V AC CLASS 2 POWER SUP- PLY ONLY.

-51-

Page 51
Image 51