Error

 

Cause

 

Remedy

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SE T

This message appears if

Set length between 0.25"

 

 

LENGT H!

 

length has not been set when

 

and 11.80" (6.4 and 299.7

 

 

 

 

Rotate and Repeat Legend

 

mm).

 

 

 

 

are selected.

 

 

 

 

 

 

 

 

 

 

SYSTEM

This message appears if

• Contact Technical Support at

 

 

ERROR!

 

there is a problem with the

 

866-871-4571 (outside the

 

 

 

 

machine’s software.

 

US, refer to page 70 for

 

 

 

 

 

 

contact information).

 

 

 

 

 

 

 

 

 

TEXT

This message appears if the

Reduce the size of the

 

 

TOO HIGH!

 

size of the text is larger than

 

characters or install a wider

 

 

 

 

the width of the installed

 

tape.

 

 

 

 

tape.

 

 

 

 

 

 

 

 

 

 

 

TEXT

This message appears if the

Delete some of the text or

 

 

TOO LONG!

 

length of the text is longer

 

increase the set label length.

 

 

 

 

than the label length that has

 

 

 

 

 

 

been set using the Length

 

 

 

 

 

 

function.

 

 

 

 

 

This message appears if the

Delete Rotate function.

 

 

 

 

number of characters is

 

 

 

 

 

 

more than the limit of an

 

 

 

 

 

 

installed tape when Rotate

 

 

 

 

 

 

function is selected.

 

 

 

 

 

 

 

 

 

 

 

VALUE

This message appears if the

Press the key of the value

 

 

TOO SMALL!

 

last value set to be printed is

 

that is greater than the value

 

 

 

 

less than the s elected value

 

in the text.

 

 

 

 

in the text using the

 

 

 

 

 

 

Serialize function.

 

 

 

 

 

 

 

 

 

 