Paradise 205486 REV F manual 1:Monitor & Control Connector, J4, Signal, Type, Function, Notes

Models: 205486 REV F

1 124
Download 124 pages 61.17 Kb
Page 26
Image 26
Table 3-1: Monitor & Control Connector, J4

Table 3-1: Monitor & Control Connector, J4

Signal

 

Type

Function

Pin

Notes

Mute Input

 

Closure to Ground

Disables DC Power to SSPA

B

Unit Powers up Muted, This line must

 

 

 

 

 

be pulled to ground (V or d) to enable

 

 

 

 

 

amplifier

 

 

 

 

 

 

Auxiliary Input

Closure to Ground

Auxiliary Fault Input

P

 

 

Summary Alarm

Form C Relay

Closed on Fault

L

L-a : normally open

 

 

 

Common

a

 

 

 

 

 

Open on Fault

b

a-b : normally closed

Auxiliary Alarm

Form C Relay

Closed on Fault

N

N-Z : normally open

 

 

 

Common

Z

 

 

 

 

 

Open on Fault

M

Z-M: normally closed

 

 

Open Collector

High on Fault

W

Reserved

 

 

 

 

 

Auxiliary Alarm

Open Collector

High on Fault

G

Requires external pull-up

Voltage Alarm

Open Collector

High on Fault

H

Requires external pull-up

 

 

 

 

 

Current Alarm

Open Collector

High on Fault

J

Requires external pull-up

Temperature Alarm

Open Collector

High on Fault

X

Requires external pull-up

 

 

 

 

 

 

Spare Fault

 

Open Collector

High on Fault

S

Requires external pull-up

RF Power Detector

Analog Output

Relative Indication of RF Output

R

+4.0 vdc at Psat

 

 

 

Power

 

 

 

Gain Adjust Input

Analog Input

Adjusts Amplifier Gain over 20dB

A

2.5 vdc = Max Gain 75dB

 

 

 

range

 

0.5 vdc = Min Gain 55dB

Block Up Converter

Open Collector

High on Fault

f

Requires external pull-up

Alarm

 

 

 

 

 

 

RS232 / RS485

Closure to Ground

Selects Serial Communication

D

Default is RS 485; pull to ground (V)

Select

 

 

 

 

to enable RS 232

RS 485 TX-

or

Serial TX Output

Serial Link Data Port

E

 

 

RS232 OUT

 

 

 

 

 

 

 

 

 

 

 

RS 485 RX-

or

Serial RX Input

Serial Link Data Port

F

9600 default Baud Rate

RS232 IN

 

 

 

 

 

 

RS 485 TX+

Serial TX Output

Serial Link Data Port

T

 

 

 

 

 

 

 

 

RS 485 RX+

Serial RX Input

Serial Link Data Port

U

 

 

GND

 

Signal Ground

Common Signal Return

V, d

 

 

 

 

 

 

 

 

Baud Select 0

Closure to Gnd

Select Baud Rate & Protocol

j

Refer to

Appendix C

Baud Select 1

Closure to Gnd

Select Baud Rate & Protocol

e

Refer to

Appendix C

 

 

 

 

 

PGM Switch

 

Flash Firmware Port

g

Reserved for Programming

PGM CLK

 

 

Flash Firmware Port

c

Reserved for Programming

 

 

 

 

 

 

PGM-Sout

 

 

Flash Firmware Port

K

Reserved for Programming

PGM-Sin

 

 

Flash Firmware Port

Y

Reserved for Programming

 

 

 

 

 

 

PGM +5V

 

 

Flash Firmware Port

h

Reserved for Programming

PGM Enable

 

Flash Firmware Port

C

Reserved for Programming

 

 

 

 

 

 

 

26

205486 REV F

Operations Manual, HPA2, Compact Outdoor SSPA

Page 26
Image 26
Paradise 205486 REV F manual 1:Monitor & Control Connector, J4, Signal, Type, Function, Notes