10.5.2 Example 2

10.5.2 Example 2

Change SSPA Attenuation to 20 dB (55dB gain)

SSPA Network Address = 5

Host Computer Network Address = 10

Request ID = 0x6F

 

 

 

Table 10-12: Example 2 PC Request String

 

 

 

 

Byte

Byte

 

Description

Position

Value

 

 

 

(hex)

 

 

 

 

 

 

1

AA

 

Frame Sync Byte 1

2

55

 

Frame Sync Byte 2

3

5

 

Destination Address of the unit

4

A

 

Source address of Request originating PC Host

5

0

 

Protocol Version Compatibility Field must be always 0

6

6F

 

Request ID is 111

7

0

 

Command “Set request” designator

8

0

 

Data tag “0” indicates access to SSPA Settings

9

5

 

Data address 5 indicates access to SSPA attenuation

10

1

 

Data length is 1 byte

11

C8

 

Data 200 - 20.0 dB x 10 attenuation

 

 

 

 

12

4C

 

Arithmetic checksum of bytes 3 to 11

 

 

 

 

 

 

Table 10-13. Example 2 SSPA Response String

 

 

 

 

Byte

Byte

 

Description

Position

Value

 

 

 

(hex)

 

 

 

 

 

 

1

AA

 

Frame Sync Byte 1

 

 

 

 

2

55

 

Frame Sync Byte 2

3

A

 

Destination Address of PC request originator

4

5

 

Source address of the respondent

5

0

 

Protocol Version Compatibility Field must be always 0

6

6F

 

Echo of the Originator’s Request ID byte

7

2

 

“Set Response” designator

 

 

 

 

8

0

 

Data Tag “0” was accessed

 

 

 

 

9

0

 

Data address omitted and replaced with error status “0” – no errors.

 

 

 

 

10

1

 

Data length is 1 byte

11

C8

 

Data 200 - 20.0 dB x 10 attenuation successfully set

12

49

 

Arithmetic checksum of bytes 3 to 11