Figure 11-4: Verification to Change Protocol

11.2 Configuring SSPA and PC to work with terminal mode protocol

Each unit is shipped from the factory with “String” type of protocol selected as the default serial protocol. To switch the SSPA to work with Terminal mode protocol, the user must use the supplied M&C utility software and establish a connection with the SSPA (see Compact Outdoor Amplifier Quick Start Guide for details).

1.Establish connection with the SSPA by using Paradise Datacom Quick Start Cable and PC’s RS232 serial port.

2.Start and configure Paradise Datacom Universal M&C utility. Make sure the M&C software has steady connection with the SSPA (green light at upper left corner of Status screen).

3.On the “Settings” tab, select the “Serial Protocol” setting as shown on Figure 11-3.

Figure 11-3: Universal M&C Settings Screen, Modifying Protocol Select

4.Select “Terminal’ in selection box. A dialog window will appear prompting you to accept the change in protocol See Figure 11-4.

Figure 11-4: Verification to Change Protocol

5. Cycle power to the unit. The unit is now configured to use Terminal mode serial protocol.