Figure 7-8: M&C Program “SSPA Settings” window

Each amplifier can be configured for redundancy by the Paradise Datacom Universal M&C software that ships along with each unit. Using the Quick-Start cable, connect each amplifier to the PC and run the M&C program. Select the “Settings” tab from the main form. The “Settings” window will appear as shown in Figure 7-8.

1.System Mode: Each SSPA’s System Mode must be set to “1:1 Redundant Mode”

2.Choose a Hierarchical Address for each amplifier. HPA 1 means this SSPA will use the RF switch position 1 as its On Line state position. HPA 2 will then use RF switch position 2.

3.Redundancy Startup State: The amplifier which is desired to be on line should be set “On Line”. The other amplifier should be set as “Standby”.

All settings are valid as soon as the operator sets them on the SSPA Settings window. The SSPA’s redundant operation can be verified by monitoring the RF Switch Fault indicator as shown in Figure 7-15.

Figure 7-8: M&C Program “SSPA Settings” window

50

205486 REV F

Operations Manual, HPA2, Compact Outdoor SSPA