Paradyne 8620, 8820 32. DS1-EXT MIB, pdnDs1ExtConfLineLengthType RW, pdnDs1ExtConfLineLength RW

Models: 8620 8820

1 108
Download 108 pages 7.87 Kb
Page 43
Image 43
Table 1-32. DS1-EXT MIB

1. Network Management Specification

The various objects supported are shown in the following table.

Table 1-32. DS1-EXT MIB

Table

Comments

 

 

pdnDs1ExtConfTable

Supported objects:

 

pdnDs1ExtConfLineLengthType

 

pdnDs1ExtConfLineLength

 

pdnDs1ExtConfLineBuildOut

 

pdnDs1ExtConfConnector

 

 

5.5.1pdnDs1ExtConfLineLengthType (RW):

This entry specifies the type of loop length for the interface. The posibble values are shortHaul(1), longHaul(2). short-haul is intended for intra-building use. long-haul is intended for inter-building use. The default value is long-haul.

5.5.2pdnDs1ExtConfLineLength (RW):

This entry specifies the loop length, in feet, for a short-haul DS1 line. This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineBuildOut object. Only one of the two can be used for configuration at a time, based on the pdnDs1ExtConfLineLengthType object. The default value is feet000To133.

5.5.3pdnDs1ExtConfLineBuildOut (RW):

This entry specifies the line build out, in decibels, for a long-haul DS1 line. The possible values are: dB0Pnt0(1), dB7Pnt5(2), dB15Pnt0(3), dB22Pnt5(4). The default value is dB0Pnt0(1). This object only applies to DS1 interfaces.

5.5.4pdnDs1ExtConfConnector (RW):

This entry specifies the type of connector to be used. This object only applies to G.703 interfaces. The possible values are: bnc(1), rj48(2). The default value is rj48(2).