Operation and Maintenance
5-10 9664-A2-GB20-00
March 2000

Table 5-5. Device Messages (5 of 5)

Message What To DoWhat It Indicates
Test Active No higher priority health
and status messages exist,
and a test is running.
HContact service provider if test
initiated by the network.
HWait until the test ends and
message clears.
HCancel all tests from the Test
screen (Path: main/test).
HStop the test from the same
screen the test was started
from.
User Interface
Already in Use Two Telnet sessions are
already in use when an
attempt to access the
menu-driven user interface
through the COM port is
made.
IP addresses and logins of
the users currently
accessing the interface are
also provided.
HWait and try again.
HContact one of the IP address
user and request that they log
off.
User Interface Idle Previously active session is
now closed/ended, and
access via the COM port is
now available.
Log on to the FrameSaver unit.
Session has been ended
due to timeout. No action needed.
Value Out of Range CIR entered for the DLCI is
a number greater than the
maximum allowed.
Enter a valid CIR.
B1 Channel: 0 – 64000
Both B-Channels: 0 – 128000.
Excess Burst Size (Be)
entered for the DLCI is a
number greater than the
maximum allowed.
Enter a valid Be.
B1 channel: 0 – 64000
Both B-Channels: 0 – 128000.
DLCI Number entered is
less than 16 or greater
than 1007.
Enter a valid number
(16 – 1007).