Operation and Maintenance

System and Test Status Messages

System and test status information is selected from the Status menu.

Main Menu Status System and Test Status

The following information is included on this screen:

HSelf-Test Results Messages

HHealth and Status Messages

HTest Status Messages

Self-Test Results Messages

These self-test result messages appear in the Self-Test Results field at the top of the System and Test Status screen.

Table 5-6. Self-Test Results Messages

Message

What It Indicates

What To Do

Failure xxxxxxxx

An internal failure occurred (xxxxxxxx represents an

8-digit hexadecimal failure code used by service personnel).

Record the failure code before resetting the unit; otherwise, the error information will be lost.

1.Record the failure code.

2.Reset the unit.

3.Contact your service representative.

Passed

No problems were found during power-on or reset.

No action needed.

5-12

March 2000

9664-A2-GB20-00

Page 106
Image 106
Paradyne 9664 System and Test Status Messages, Main Menu → Status → System and Test Status, Self-Test Results Messages

9664 specifications

The Paradyne 9664 is a high-performance broadband multiplexer designed for the reliable transmission of data over various types of communication media. This advanced device enables businesses and service providers to integrate multiple digital signal formats into a single high-capacity transmission line, thereby optimizing bandwidth usage and enhancing overall network efficiency.

One of the standout features of the Paradyne 9664 is its ability to support multiple protocols, including T1, T3, and Ethernet. This versatility allows users to consolidate their networking infrastructure, reducing the need for multiple types of equipment and simplifying network management. The device's capability to handle diverse data formats not only makes it suitable for various applications but also ensures future-proofing as technology continues to evolve.

The Paradyne 9664 utilizes advanced Time Division Multiplexing (TDM) technology, which enables it to allocate bandwidth dynamically based on real-time traffic demands. This intelligent bandwidth allocation helps to reduce latency and ensures that critical applications receive the necessary resources when needed. Additionally, the system features robust error correction algorithms to minimize data loss during transmission, enhancing the reliability of the network.

In terms of characteristics, the Paradyne 9664 is designed with user-friendliness in mind. Its modular architecture allows for easy upgrades and scalability, making it an attractive option for growing businesses. The device also features a comprehensive set of diagnostic tools, enabling network administrators to monitor performance and troubleshoot issues effectively.

Another noteworthy aspect of the Paradyne 9664 is its security features. With built-in encryption capabilities and the option to implement virtual private networks (VPNs), the device provides secure data transmission, protecting sensitive information from unauthorized access.

Overall, the Paradyne 9664 stands out as a robust, flexible, and efficient solution for organizations looking to enhance their communication networks. With its combination of advanced technologies, user-centric design, and strong security measures, it is well-equipped to meet the demands of today’s dynamic networking environment, making it an essential tool for businesses aiming to maintain a competitive edge in an increasingly connected world.