Operation and Maintenance

5-3

9664-A2-GB20-00 March 2000
Viewing LEDs and Control Leads
The FrameSaver unit’s faceplate includes LEDs (light-emitting diodes)
that provide status on the FrameSaver unit, its network interface, and its user
data port.
00-16654
OK
ALM
TST
OK
OK
9664
NETWORK PORT

FrameSaver

TM

SLV

FrameSaver

®

SLV

The Display LEDs and Control Leads screen allows you to monitor a remote unit
and is useful when troubleshooting control lead problems. The appropriate
interfaces are shown on this screen, with the appropriate status highlighted.
Main Menu
Status
Display LEDs and Control Leads
Display LEDs & Control Leads Screen
main/status/leds 9664
Device Name: Node A 5/26/1999 23:32
DISPLAY LEDS & CONTROL LEADS
SLOT: 1 - LL S/T FR NAM
GENERAL NETWORK1 Port-1
OK OK OK
Alarm TXD
Test RXD
DTR
RTS(Control)
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu MainMenu Exit
Refresh
Refresh the screen to view control lead transitions. LED and control lead
descriptions are in the sections that follow.