D-1

9664-A2-GB20-00 March 2000
Technical Specifications D

Table D-1. FrameSaver SLV 9664 Unit Technical Specifications (1 of 2)

Specification Criteria

Approvals
EMC (Class A)
Network
CE
Safety
CISPR22, VCCI
CTR 3
73/23/EEC, 89/336/EEC, 91/263/EEC
EN 60950
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
32°F to 122°F (0°C to 50°C)
–4°F to 158°F (–20°C to 70°C)
5% to 85% (noncondensing)
Withstands normal shipping and handling
Weight 2.85 lbs. (1.29 kg)
Physical Dimensions
Height
Width
Depth
2.9 inches(7.4 cm)
8.5 inches (21.6 cm)
12.5 inches(31.8 cm)
Power
Input
Output
100 – 240 Vac, 50/60 Hz, 0.7A
12 Vdc, 2.5 A, 1.0A minimum
Power Consumption
and Dissipation 6.26 watts, 125mA at 100 Vac (Japan)
Result: 21.36 Btu per hour
7.0 watts, 76.6mA at 240 Vac (Europe)
Result: 23.88 Btu per hour