The following is a list of the jumper functions on the ACRCOMM module:

Jumper

 

Description

 

 

 

J1

 

COM1 RS-422 Termination Resistor Select

 

 

(see Table 4, on page 6)

 

 

 

J2

 

COM1 RS-422 Termination Resistor Select

 

 

(see Table 4, on page 6)

 

 

 

J3

 

COM2 RS-422 Termination Resistor Select

 

 

(see Table 4, on page 6)

 

 

 

J4

 

COM2 RS-422 Termination Resistor Select

 

 

(see Table 4, on page 6)

 

 

 

J5

 

Not used with the ACR1505

 

 

 

J6

 

Not used with the ACR1505

 

 

 

J7

 

COM1 and COM2 Autobaud Detect Enable

 

 

(see Table 4, on page 6)

 

 

 

J8

 

Reserved

 

 

 

J9

 

Reserved

 

 

 

J10

 

Reserved

 

 

 

Table 3 ACRCOMM Jumper Functions

RS-422 Communication Ports Line Terminator Jumpers (J1 thru J4)

These jumpers provide termination resistors for the RS-422signals. For jumper locations, see Figure 2 on page 5.

Factory Default

........................................

 

 

 

Jumpers in

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication Ports Termination Jumpers

 

 

 

 

 

 

 

 

 

 

Signal

 

 

Jumper

 

Termination

 

No Termination

 

 

 

 

 

 

 

 

 

 

RXD1A/RXD1B

 

 

J1

 

Jumper In

 

Jumper Out

 

 

 

 

 

 

 

 

 

 

TXD1A/TXD1B

 

 

J2

 

Jumper In

 

Jumper Out

 

 

 

 

 

 

 

 

 

 

RXD2A/RXD2B

 

 

J3

 

Jumper In

 

Jumper Out

 

 

 

 

 

 

 

 

 

 

TXD2A/TXD2B

 

 

J4

 

Jumper In

 

Jumper Out

Table 4 ACRCOMM RS-422 Termination Jumpers

6 – ACRCOMM and ACREXPAXIS User’s Guide