Battery Enable Jumpers (J5 and J6)

These jumpers are not used with the ACR1505 Controller.

Autobaud Detect Jumper (J7)

This jumper enables or disables the Autobaud detect feature of the serial communications channels on the ACRCOMM module. This jumper works in conjunction with the COM1 Startup Mode (P7013) and COM2 Startup Mode (P7029) parameters. For more information, see “Miscellaneous Parameters P6912-P7029” in the “ACR Motion Controller’s User’s Guide Part 2”.

When the COM1/2 Startup Mode parameters (bit 15) are set to zero (factory default-0), the Autobaud detect is enabled and the Autobaud Detect Jumper (J7) is ignored.

When the COM1/2 Startup Mode parameters (bit 15) are set to one, the Autobaud Detect Jumper (J7) defines the autobaud detect function (see Table 5). For jumper locations, see Figure 2 on page 5.

Factory Default

Autobaud Detect Enabled

 

 

 

 

 

 

 

Autobaud Detect Jumper

 

 

 

 

 

 

 

 

 

Function

 

 

J7

 

 

 

 

 

Autobaud Detect Enabled

 

 

ON

 

 

 

 

 

Autobaud Detect Disabled

 

 

OFF

 

Table 5 ACRCOMM Autobaud Detect Jumper

 

 

Chapter 1 – ACRCOMM – 7

Page 11
Image 11
Parker Hannifin P/N88023735/01A manual Battery Enable Jumpers J5 and J6, Autobaud Detect Jumper J7