Battery Enable Jumpers (J5 and J6)
These jumpers are not used with the ACR1505 Controller.
Autobaud Detect Jumper (J7)
This jumper enables or disables the Autobaud detect feature of the serial communications channels on the ACRCOMM module. This jumper works in conjunction with the COM1 Startup Mode (P7013) and COM2 Startup Mode (P7029) parameters. For more information, see “Miscellaneous Parameters
When the COM1/2 Startup Mode parameters (bit 15) are set to zero (factory
When the COM1/2 Startup Mode parameters (bit 15) are set to one, the Autobaud Detect Jumper (J7) defines the autobaud detect function (see Table 5). For jumper locations, see Figure 2 on page 5.
Factory Default | Autobaud Detect Enabled | ||||
|
|
|
|
|
|
| Autobaud Detect Jumper |
|
| ||
|
|
|
|
|
|
| Function |
|
| J7 |
|
|
|
| |||
| Autobaud Detect Enabled |
|
| ON |
|
|
|
| |||
| Autobaud Detect Disabled |
|
| OFF |
|
Table 5 ACRCOMM Autobaud Detect Jumper |
|
|
Chapter 1 – ACRCOMM – 7 –