XP10 Connector
The XP10 connector provides +5 VDC TTL I/O for INTCAP and other special functions. For connector locations, see Figure 3 on page 11.
Voltage |
|
|
|
| +5 VDC |
|
| |
Current Rating |
|
|
|
| 0.100A maximum |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| XP10 Pinout |
|
| ||
|
|
|
|
|
|
|
|
|
| Definition |
| Pin |
|
| Definition |
| Pin |
|
|
|
|
|
|
| ||
| EXP_IN0 |
| 1 |
|
| EXP_IN1 |
| 2 |
|
|
|
|
|
|
| ||
| EXP_IN2 |
| 3 |
|
| EXP_IN3 |
| 4 |
|
|
|
|
|
|
| ||
| EXP_IN4 |
| 5 |
|
| EXP_IN5 |
| 6 |
|
|
|
|
|
|
| ||
| EXP_IN6 |
| 7 |
|
| EXP_IN7 |
| 8 |
|
|
|
|
|
|
| ||
| EXP_OUT0 |
| 9 |
|
| EXP_OUT1 |
| 10 |
|
|
|
|
|
|
| ||
| RESERVED |
| 11 |
|
| RESERVED |
| 12 |
|
|
|
|
|
|
| ||
| RESERVED |
| 13 |
|
| RESERVED |
| 14 |
|
|
|
|
|
|
|
|
|
Table 12 EXPAXIS XP10 Connector Pinout
F1 Fuse
When replacing fuses for the EXPAXIS module, use the following tables to determine the correct part numbers for different vendors.
For fuse location, see Figure 3 on page 11.
Voltage | +5 VDC |
Current Rating | 0.250A |
Type | Littelfuse 454.500 |
| Time Delay Fuse |
Hardware Wiring
Analog I/O—XP2
The Analog I/O connections on the EXPAXIS module is a 40 Pin Header. To convert the XP2 connector (EXPAXIS module) for use with the P2 connector (ACR1505), use the DXP2 cable assembly (part number PWH80500) supplied with the EXPAXIS module.
– 16 – ACRCOMM and ACREXPAXIS User’s Guide