Patton electronic user manual Distance Chart 2160 Series Optimal Mode TCPAM-128

Models: 2160

1 113
Download 113 pages 32.92 Kb
Page 25
Image 25

Model 2160 Series User Manual2 • Applications overview

Distance Chart 2160 Series – Optimal Mode (TCPAM-128)

Table 5. Distance Chart Model 2160 Series – Optimal Mode

 

 

Line Rate

 

 

 

Distance

 

 

 

 

 

 

 

 

 

 

 

 

Line

2160

2161

2162

26 AWG/0.4mm

24 AWG/0.5mm

22 AWG/0.65mm

Speed

2-Wire

4-Wire

8-Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N =

kbps

kbps

kbps

kft

km

kft

km

kft

km

 

 

 

 

 

 

 

 

 

 

7

448

896

1792

20.0

6.1

24.0

7.3

31.0

9.4

8

512

1024

2048

19.0

5.8

23.0

7.0

30.0

9.1

10

640

1280

2560

18.0

5.5

20.5

6.2

28.0

8.5

11

704

1408

2816

17.0

5.2

19.0

5.8

26.5

8.1

16

1024

2048

4096

16.0

4.9

18.0

5.5

24.5

7.5

20

1280

2560

5120

15.0

4.6

17.0

5.2

23.0

7.0

22

1408

2816

5632

14.0

4.3

15.5

4.7

21.0

6.4

27

1728

3456

6912

13.0

4.0

14.5

4.4

20.0

6.1

34

2176

4352

8704

12.0

3.7

14.5

4.4

18.5

5.6

39

2496

4992

9987

11.0

3.4

13.0

4.0

17.0

5.2

44

2816

5362

11264

10.0

3.0

12.0

3.7

15.5

4.7

53

3392

6784

13568

9.0

2.7

10.5

3.2

13.5

4.1

73

4672

9344

18688

8.0

2.4

9.5

2.9

12.5

3.8

89

5696

11392

22784

7.0

2.1

8.5

2.6

10.5

3.2

110

7040

14080

28160

6.0

1.8

7.0

2.1

9.0

2.7

125

8000

16000

32000

5.0

1.5

6.0

1.8

7.5

2.3

152

9728

19456

38912

4.0

1.2

4.5

1.4

6.0

1.8

164

10496

20992

41984

3.0

0.9

3.5

1.1

4.5

1.4

198

12792

25584

51168

2.0

0.6

2.5

0.8

3.0

0.9

 

 

 

 

 

 

 

 

 

 

Distance charts

25

Page 25
Image 25
Patton electronic Distance Chart 2160 Series Optimal Mode TCPAM-128, Distance Chart Model 2160 Series Optimal Mode