Pelco C3463M-B manual Aux, Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 Mode

Models: C3463M-B

1 72
Download 72 pages 46.86 Kb
Page 46
Image 46

AUX

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA> <MOTION>

<AUTO TRACKING> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

AUX

AUX 1 MODE

TOGGLE

DWELL TIME (SECS)

1

AUX 2 MODE

TOGGLE

DWELL TIME (SECS)

1

<EDIT SCHEDULE>

 

BACK

 

EXIT

 

An auxiliary output is a configurable signal from the dome back box that can trigger another device to operate. An auxiliary output can be configured to trigger from an alarm or from a controller.

An AUX 1 command from the controller will activate the relay in the dome and operate the device that is connected to the relay. The output of AUX 1 can be connected to the alarm input of a system switch to activate automatic monitor switching and recording.

An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the device that is connected to it.

The following are the available AUX mode settings:

TOGGLE (default): Changes the state of the auxiliary output every time an AUX command is received from the controller.

LATCHING: Must receive an AUX ON/AUX OFF command from the controller to turn the auxiliary output on/off.

MOMENTARY: An AUX ON command from the controller turns the auxiliary output on for the configured DWELL TIME. The auxiliary output will automatically turn off when the dwell time is finished.

EDIT SCHEDULE

The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 53) with the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also, the Holiday feature cannot be accessed from the Edit Schedule menu.

For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on page 54.

*This setting applies to Pressurized Spectra IV dome systems only.

46

C3463M-B (2/11)

Page 46
Image 46
Pelco C3463M-B Aux, Back Exit AUX AUX 1 Mode Toggle Dwell Time Secs AUX 2 Mode, Dwell Time Secs Edit Schedule Back Exit