ALERT
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> ACK ALERT
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS |
|
|
|
| ALERT |
<CAMERA> |
|
|
|
| REPEAT |
<MOTION> |
|
|
|
| ACK ACTION |
<AUTO TRACKING> |
|
|
|
| ACTIVATE AUX |
<POWER UP> |
|
|
|
| <CURRENT READING> |
<LINE SYNC> |
|
|
|
| RESET ALERT |
<PRESETS> |
|
|
|
| BACK |
<PATTERNS> |
|
|
|
| |
<ZONES> |
|
|
|
| EXIT |
<WINDOW BLANKING> |
|
|
|
|
|
<ALARMS> |
|
|
|
|
|
<AUX> |
|
|
|
|
|
<TITLE TEXT> |
|
|
|
|
|
<ALERT> |
|
|
|
|
|
<CLEAR> |
|
|
|
|
|
<PASSWORD> |
|
|
|
|
|
<CLOCK> |
|
|
|
|
|
<EVENT> |
|
|
|
|
|
BACK |
|
|
|
|
|
EXIT |
|
|
|
|
|
NOTE: The Alert option applies to Pressurized Spectra IV dome systems only. Spectra IV systems that are not pressurized will not display this menu item.
Sensors strategically placed inside the pressurized dome system continually monitor pressure, temperature, and dew point. If internal conditions reach unacceptable levels, an alert message appears on the screen describing the alert condition. For example, if pressure drops below 1 psig, LOW PRESSURE is displayed.
The following system conditions will trigger an alert message:
System Condition | Alert Message |
Temperature is above 140°F (60°C) | HIGH TEMPERATURE |
Temperature is below | LOW TEMPERATURE |
Pressure is above 13 PSIG | HIGH PRESSURE |
Pressure is below 1 PSIG | LOW PRESSURE |
The difference between the temperature and | DEW POINT (HIGH HUMIDITY) |
the dew point is less than or equal to 3°C. |
|
The alert message will be repeatedly displayed until the system controller acknowledges the alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message changes to the configured acknowledge action (ACK ACTION). If the alert condition remains active after a period of time, the alert message reappears on the monitor, restarting the alert message cycle. This cycle will continue to repeat until the alert condition is resolved.
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system controller acknowledges the alert condition. The following are the settings:
CONSTANT: The alert message is continuously displayed until acknowledged.
15 MIN: The alert message is displayed every 15 minutes for a
30 MIN: The alert message is displayed every 30 minutes for a
60 MIN: The alert message is displayed every 60 minutes for a
OFF: The alert message is disabled and will not be displayed.
ACK ACTION
Set ACK ACTION to configure the frequency at which an alert message is displayed after the alert condition has been acknowledged. The following settings are available:
ALWAYS ON: The alert message is displayed until alert conditions are cleared.
OFF 8 HRS: The alert message is turned off for 8 hours. Message returns after 8 hours if the alert condition persists.
OFF 24 HRS: The alert message is turned off for 24 hours. Message returns after 24 hours if the alert condition persists.
OFF 48 HRS: The alert message is turned off for 48 hours. Message returns after 48 hours if the alert condition persists.