WALL

 

 

Fig. # 17

TERMINATION

 

 

 

VENTING CHART

 

 

 

A

B

C

D

 

Pipe length

 

Minimum rise

Pipe length

Maximum run

 

Maximum

 

 

 

 

 

68 1/2”

24”

18"

1'

 

74 1/2”

30”

76"

5'

 

80 1/2”

36”

11' 2 1/8"

10'

 

86 1/2”

42”

16'

15'

 

92 1/2”

48”

20’ 10 1/4”

20'

 

For other rise/run combinations see chart below

24" Pipe length minimum

NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used but must be constrained to the boundaries of this chart. A total of 3 90° elbows or combination of other elbows equalling 90° can be used without reducing horizontal run. For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported.

*Minimum Vent Pipe Centerline Height

050505-36