PGS TC36 AR manual Control Box, Hearth Extension, Fig. # 10 MANUAL MILLIVOLT VALVE, MAX 1/4

Models: TC36 AR

1 36
Download 36 pages 31.6 Kb
Page 8
Image 8
CONTROL BOX

CONTROL BOX

The gas control system is housed in a control box remote of the fi replace. Flexible conduits attach the control box to the fi replace and house all the plumbing and wiring to the burner. This unique design allows the control box to be mounted in a variety of positions on the right or left side of the fi replace. The box can be framed into the front right or left face or the right or left sidewall of the fi replace enclosure. As the control system is attached at the factory to exit the right side of the fireplace, please see "Control Box Relocation" section to move the control box to exit the left side.

Caution: When positioning the control box, do not over bend the conduit or use excessive force, as damage may occur.

1)Remove window frame latch tool and set aside.

2)Remove 4 screws holding control panel in place and carefully lift off over the control knobs, being sure not to damage wires and connections to the "Pilot Flame" indi- cator (millivolt control system only). Carefully disconnect wires from indicator, and set aside.

3)Attach control box to framing at predetermined depth, allowing room for wall fi nishing material. Side brackets can be adjusted for a trim fi t.

4)Attach control box to framing at predetermined depth, allowing room for wall fi nishing material. Side brackets can be adjusted for a trim fi t.

5)Replace door/inner frame assembly and fasten in place.

Fig. # 10 MANUAL MILLIVOLT VALVE

PILOT

 

CONTROL

 

DOOR AND

FLAME

BATTERY SPARK

FRAME

INDICATOR

IGNITER

 

GAS

BURNER CONDUIT VALVE SWITCH

Note: Gas supply plumbing must be completed and the

6) Reconnect "Pilot Flame" indicator wiring and reinstall

spark igniter battery or backup batteries installed before

control panel.

reinstalling the front control panel.

 

Fig. # 11

WINDOW

FRAME

1"

MAX

1/4"

SUB-

HEARTHFLOOR EXTENSION

WINDOW

TRACK

HEARTH EXTENSION

While a hearth extension is not required for this fi replace, one is recommended for aesthetic reasons. The hearth extension should be noncombustible and must not be any more than 1" above the bottom of the fi replace. If thicker, fi replace must be raised up accordingly.

Caution: Hearth extensions thicker than 1" will interfere with the window frame.

8 36ARB2

050505-36

Page 8
Image 8
PGS TC36 AR manual Control Box, Hearth Extension, Fig. # 10 MANUAL MILLIVOLT VALVE, MAX 1/4