PGS TC36 AR manual D E Af B C, Wall Or, Mantel, Clearance, 63/4 1 1/2, Support

Models: TC36 AR

1 36
Download 36 pages 31.6 Kb
Page 4
Image 4
D

COMBUSTIBLE FRAMING AND

FINISH WALL ABOVE STANDOFFS

MAY USE COMBUSTIBLE FACING

MATERIAL IN THIS AREA

NON-COMBUSTIBLE

FINISH MATERIAL

SEE FIG #7

D

E

AF

B

C

TOP OF LINTEL BAR

FIREPLACE FRONT

Fig. # 2

STEEL FRAMING

STANDOFFS

NON-COMBUSTIBLE ZONE.

DO NOT INSTALL ANY

COMBUSTIBLE MATERIAL,

ELECTRICAL WIRING OR

GAS PLUMBING IN THIS

AREA.

MANTEL CLEARANCE CHART

REF.

MANTEL

REF.

*CLEARANCE

 

 

A

9"

D

B

6"

E

C

3"

F

**DEPTH 12"MANTEL

63/4"

1 1/2"

Minimum Clearances to Combustibles:

Side standoffs

0 in.

(0 mm)

Back standoffs

0 in.

(0 mm)

Top standoffs

0 in.

(0 mm)

Bottom of appliance

0 in.

(0 mm)

Adjacent sidewall

4 in.

(102 mm)

Ceiling to appliance

24 in.

(610 mm)

*Mantel to appliance

See Figure #2

**Maximum

 

 

Mantel extension

See Figure #2

Mantel support

4 in.

(102 mm)

Vertical vent pipe

1-3/4 in.

(45 mm)

Horizontal vent pipe

 

 

Top

1-3/4 in.

(45 mm)

Sides

1-3/4 in.

(45 mm)

Bottom

1-3/4 in.

(45 mm)

Fig. # 3

CEILING

MANTEL

ADJACENT

 

 

WALL OR

 

MANTEL

 

SUPPORT

UNIT MAY BE RECESSED UP TO 6" WITH NON-COMBUSTIBLE MASONRY TYPE MATERIAL

4 36ARB2

050505-36

Page 4