ROOF TERMINATION

Fig. # 18

VENTING CHART

A

B

C

D

Pipe length

Minimum rise

Pipe length

Maximum run

Maximum

 

 

 

68 1/2”

24”

26 5/16"

1'

 

 

 

 

74 1/2”

30”

84 3/8"

5'

 

 

 

 

80 1/2”

36”

11' 10 1/2"

10'

 

 

 

 

86 1/2”

42”

16' 8 1/2"

15'

 

 

 

 

92 1/2”

48”

21’ 6 5/8”

20'

 

 

 

 

For other rise/run combinations see chart below

24" Pipe length minimum

14 36ARB2

NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used but must be con- strained to the boundaries of this chart. A total of 4 90° elbows or combination of other elbows equalling 90° can be used without reducing horizontal run. For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported.

050505-36

Page 14
Image 14
PGS TC36 AR manual Roof Termination