Antenna Installation and Alignment

It is recommended that the Satellite dish antenna be installed by your local DMX Affiliate. It is imperative that the dish be securely and safely mounted, and pointed accurately at the Satellite. Brief instructions are presented here for completeness.

Satellite Dish Installer: Ground the RF input cable to the building grounding system as close as possible to the point of building entry. Refer to the National Electric Code (NEC) Article 820-40.

The following steps describe the process to properly set up, position, and connect the antenna using the DR500 Receiver:

1.Determine the proper block converter and feed horn polarity adjustment for your area.

2.Assemble the satellite dish antenna.

3.Locate the antenna in an area with an unobstructed line of sight to the satellite coordinates (azimuth and elevation) for your area.

For information relating to satellite location and coordinates, antenna alignment, and signal acquisition, contact your DMX affiliate.

4.Pre-position the antenna to the correct azimuth and elevation coordinates by using a compass and inclinometer.

5.Pre-position the LNB to the indicated polarity setting.

6.Locate the DR500 Receiver within visual range of the antenna.

7.Connect a 75 ohm coaxial cable (RG-6, typical) from the output of the LNB to the Receiver RF IN connector.

8.Connect 120 VAC power to the DR500 Receiver – do not turn it on.

Improvise a temporary sun shade over the DR500 front panel as the LED displays may be difficult to read in direct sunlight.

9.Place the receiver in signal strength mode by depressing the power, channel up, and channel down buttons simultaneously. Alternatively, this may be done with the remote control using Preset 180.

The display reads nL, signifying it is not locked.

Channel 1 flashes on the front panel display indicating the receiver is muted

AUTH LED is Off unless the receiver is already authorized

SYNC LED is Off and remains so until the satellite is acquired

The signal strength level numbers are preceded by a minus sign (-) to differentiate them from a music channel number. Signal Quality readings vary from -00 (the strongest level) to approximately -80 (weakest level) before losing the satellite lock nL.

Rock the dish slowly from side to side and up/down around the nominal position. When the Satellite has been located, the display will read out a negative number representing signal strength and the Sync light will illuminate. Carefully move the dish to maximize signal, at which time the readout will be the least negative (closest to zero). Tighten the bolts and check that signal strength has not been disturbed by tightening the bolts.

DR500 (E-27)

Rev. C 10/94

Page 27
Image 27
Philips DR500 manual Antenna Installation and Alignment

DR500 specifications

The Philips DR500 is a cutting-edge digital radiography system designed to enhance imaging performance while ensuring a streamlined workflow and patient comfort. With a robust set of features, the DR500 combines advanced technologies to meet the needs of modern medical facilities.

One of the primary features of the Philips DR500 is its innovative detector technology. It is equipped with a high-resolution flat-panel detector that delivers exceptional image quality with minimal radiation exposure. This is crucial for patient safety while allowing healthcare professionals to achieve accurate diagnoses. The detector's fast image acquisition speeds mean that examinations can be completed more swiftly, enhancing overall operational efficiency.

The DR500 also boasts a user-friendly interface that simplifies the imaging process for radiologists and technicians alike. The touchscreen interface is intuitive, allowing for quick adjustments and settings configuration. This ease of use is complemented by automated features that reduce the likelihood of human error and improve consistency in results.

Another significant characteristic of the Philips DR500 is its versatile imaging capabilities. The system supports various radiographic applications, from general radiography to specialized procedures. This versatility makes it a valuable addition to hospitals and clinics that require a wide range of imaging modalities. It proficiently handles different patient demographics, including pediatrics and geriatrics, adapting to their unique needs.

Connectivity is a hallmark of modern imaging systems, and the DR500 excels in this area. With advanced networking capabilities, it seamlessly integrates with existing Picture Archiving and Communication Systems (PACS) and electronic health records (EHRs). This ensures that images can be stored, retrieved, and shared effortlessly among healthcare providers, improving collaboration and enabling quicker clinical decision-making.

Moreover, the Philips DR500 prioritizes patient comfort. Its ergonomic design allows for easy access and positioning, making the imaging process less stressful for patients. Enhanced features such as auto-positioning and customizable protocols contribute to a smoother experience, fostering a patient-centric approach in diagnostic imaging.

In summary, the Philips DR500 represents a significant advancement in digital radiography. Its combination of high-quality imaging, user-friendly operation, and integrated connectivity positions it as a preferred choice for healthcare facilities aiming to improve diagnostic accuracy and patient care. With its adaptable design and advanced technologies, the DR500 stands out as a powerful tool for today's medical imaging needs.