Front Panel Status | DMX/DJ Status |
Code | Message |
|
|
DR500 Status
Individual Error Messages
000 | System OK | DR500 is working properly | |
|
|
|
|
001 | System PLL | Phased locked loop error | |
|
|
|
|
002 | System LNB | Power to the low noise block (LNB) is | |
|
|
| shorted |
|
|
|
|
004 | System NV | Nonvolatile memory errors | |
|
|
|
|
|
| Combined Error Messages | |
|
|
| |
003 | System PLL | Phased locked loop error and power to the | |
|
| System LNB | low noise block (LNB) is shorted |
|
|
| |
005 | System PLL | Phased locked loop error and nonvolatile | |
|
| System NV | memory errors |
|
|
| |
006 | System LNB | Power to the low noise block (LNB) is | |
|
| System NV | shorted and nonvolatile memory errors |
|
|
| |
007 | System PLL | All system errors are detected | |
|
| System LNB |
|
|
| System NV |
|
|
|
|
|
For additional information about DR500 status messages, refer to Section 5: Maintenance and Troubleshooting.
Maintenance
The DR500 Receiver and remote controls are designed to deliver years of
Cleaning the DR500 Receiver
Before cleaning the DR500, unplug it from the wall outlet. Clean the cabinet, panel, and controls with a soft cloth lightly moistened with water.
Do not use any type of abrasive pads, scouring powders, liquid cleaners, aerosol cleaners, or solvents such as alcohol or benzene.
DR500
Rev. C 10/94