Philips LTC 3963/51 manual Duration Manual

Models: LTC 3963/51

1 64
Download 64 pages 47.19 Kb
Page 20
Image 20

SETUP (Continued)

SETTING THE ALARM

The ALARM function allows the user to set the recording duration, speed to be recorded and tape recycle for alarm recordings. When a contact clos- ure occurs at the ALARM B IN input, the VCR auto- matically enters the RECORD mode at the pre-pro- grammed ALARM recording speed. (See Alarm In, page 10 for a complete description of the ALARM sequence.) The ALARM recording duration can last according to the set value, or until the contact clos- ure is reopened.

The ALARM recording speed can be pre-pro- grammed to 09~240.

The checking signal is automatically recorded on the tape at the beginning of each ALARM recording. Later, you can easily locate the start of each record- ing by using these signals when watching a re- corded content. See “ALARM INDEX SEARCH” on page 23 for details.

See page 15 if you also want to record the date/time. The TIME/DATE display is set as follows during ALARM display.

ALARM stars () will replace the colons (:).

The recording speed will be changed to 09~240 which was selected at the “SPEED” setting in the ALARM display.

DURATION: User programmable length or time the unit stays in the alarm record mode. (MANUAL, 5 SEC, 15 SEC, 30 SEC, 1 MIN, 3 MIN, 5 MIN, 10 MIN, 30 MIN, 60 MIN or TAPE END)

ALARM RECORDING TAPE SPEED (09~240)

ALARM READY (YES or NO)

ALARM SET

DURAT I ON:

MANUAL

SPEED :

09

ALARM READY : YES

ALARM OUT :

DURAT I ON

RECYCLE

FUNCT I ONS

REW I ND , STOP I F ALARM

ALARM OUT (DURATION or PULSE)

RECYCLE FUNCTIONS

(“REWIND, STOP IF ALARM”, “REWIND, STOP” or “REWIND, RE-REC”)

ALARM Display Format Description

Notes:

When the ALARM recording ends, the VCR will return to the status it was in before the alarm was input.

Select 09 at the “SPEED” setting when the dur- ation is within 30 seconds. If the 27~240 speed is selected, electronic “marks” are not recorded on the tape and alarm index search will not operate.

1.Press the START/STOP button. The duration set- ting flashes on/off.

2.Press the UP or DOWN button until the desired setting appears on the monitor. (MANUAL, 5, 15, 30 SEC, 1, 3, 5, 10, 30, 60MIN, TAPE END)

3.Press the SET button. The record speed setting flashes on/off.

4.Press the UP or DOWN button until the desired setting appears on the monitor. (09~240 HR.)

5.Press the SET button. The alarm ready setting flashes on/off.

6.Press the UP or DOWN button to select the alarm ready function. (YES or NO)

Select “YES” if you want to start alarm record- ing even in the normal record or stop mode. Select “NO” if you do not want alarm recording in the stop mode.

7.Press the SET button. The alarm out setting flashes on/off.

8.Press the UP or DOWN button to select the alarm out function. See “ALARM OUT” on page 10 for details. (DURATION or PULSE)

9.Press the SET button.

The RECYCLE position flashes on/off.

10.Press the UP or DOWN button to select the mode at the end of tape. See “TAPE RECYCLE” on page 21 for details.

11.Press the START/STOP button.

Programming for the ALARM has been com- pleted.

Caution when input to ALARM (A) IN:

The conditions for recording an alarm input to ALARM (A) IN are fixed as follows.

Note: The ALARM READY function can be specified as YES or NO.

[Conditions for recording the input to ALARM (A) IN]

DURATION: MANUAL

MODE: 09

ALARM OUT: DURATION

RECYCLE FUNCTION: REWIND, STOP IF ALARM

19

Page 20
Image 20
Philips LTC 3963/51 manual Duration Manual